T7100: Difference between revisions
No edit summary |
No edit summary |
||
(26 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
{{CRT | |||
|Manufacturer=Tektronix | |||
|Model=T7100 | |||
|Part_nos=154-0783-00 | |||
|Description=[[micro-channel plate CRT]] | |||
|Used_in=7104; R7103 | |||
|Designers=Dennis Hall;Aris Silzars;Conrad Odenthal | |||
}} used in the [[7104]] and [[R7103]] analog 1 GHz scopes. | |||
Compared to non-MCP high-speed tubes, the T7100 uses reduced beam current and acceleration voltage | It features a [[micro-channel plate]] electron beam amplification stage. | ||
to achieve high deflection sensitivity, eliminating the need for high amplifier output voltages, thereby boosting | [[File:Micro-channel plate diagram.jpg | thumb | 550px | right | MCP diagram<br />(click image to enlarge)]] | ||
amplifier bandwidth. | Compared to non-MCP high-speed tubes, the T7100 uses reduced beam current and acceleration voltage to achieve high deflection sensitivity, eliminating the need for high amplifier output voltages, thereby boosting amplifier bandwidth. | ||
The electron beam passes through terminated helical deflection plates (both X and Y axes use | The electron beam passes through terminated helical deflection plates (both X and Y axes use this form of [[distributed deflection plates]] to achieve the necessary bandwidth), followed by an electrostatic scan-expansion lens that increases deflection 4.5 times vertically and 4 times horizontally, before it hits the micro-channel plate (MCP). | ||
this form of [[distributed deflection plates]] to achieve the necessary bandwidth), followed by | The deflection structures are described in [https://patents.google.com/patent/US4093891 US Patent 4,093,891]. | ||
an electrostatic scan-expansion lens that increases deflection 4.5 times vertically and 4 times | The scan-expansion lens is a "box lens" design, which is discussed on pages 53−55 of the ''[[Media:7104_maintenance.pdf|7104 maintenance document]]''. | ||
horizontally, before it hits the micro-channel plate which | |||
The inside walls of these channels are coated with resistive material, with a voltage of 700-1050 V applied | The MCP consists of parallel channels of 25 μm diameter and offset at a slight angle to the beam. | ||
between back and front of the plate. Electrons entering a channel hit the wall where they initiate a cascade | The inside walls of these channels are coated with resistive material, with a voltage of 700-1050 V applied between back and front of the plate. Electrons entering a channel hit the wall where they initiate a cascade of secondary electron emission like in a [https://en.wikipedia.org/wiki/Photomultiplier photomultiplier]. | ||
of secondary electron emission like in a photomultiplier. | |||
A final 10 kV potential accelerates the beam across a 3 mm gap toward the phosphor coating. | A final 10 kV potential accelerates the beam across a 3 mm gap toward the [[phosphor]] coating. | ||
The beam amplification is sufficient to view a [[Media:Tek7104-200ps-singleshot.jpg|single-shot event at 200 ps/Div]] with the naked eye. | The beam amplification is sufficient to view a [[Media:Tek7104-200ps-singleshot.jpg|single-shot event at 200 ps/Div]] with the naked eye. | ||
The Micro-channel plate's amplification degrades irreversibly with operation, in proportion to the log of total charge passed per channel or display area. | |||
For this reason, continued operation with a steady trace and especially at large beam currents must be avoided. | |||
The 7104 contains a CRT protection circuit that shuts off the beam after a time depending on the beam current. | |||
{{BeginSpecs}} | |||
{{Spec | Screen size | 8 × 10 Div. @ 8.5 mm }} | |||
{{Spec | Resolution | 17 lines / Div. }} | |||
{{Spec | Vertical deflection factor | 1 V/cm }} | |||
{{Spec | Vertical deflection impedance | 200 Ω }} | |||
{{Spec | Vertical bandwidth | 2.6 GHz (3 GHz spec claimed in maintenance document linked below) }} | |||
{{Spec | Horizontal deflection factor | 2 V/Div }} | |||
{{Spec | Horizontal deflection impedance | 365 Ω }} | |||
{{Spec | Horizontal bandwidth | 1.5 GHz }} | |||
{{EndSpecs}} | |||
==Links== | ==Links== | ||
* [http://www.vintagetek.org/wp-content/uploads/2011/10/7104-Springer-article-email-res.pdf Hans Springer: Breakthroughs throughout push scope to 1 GHz] | * [http://www.vintagetek.org/wp-content/uploads/2011/10/7104-Springer-article-email-res.pdf Hans Springer: Breakthroughs throughout push scope to 1 GHz] | ||
* [[Media:7104_maintenance.pdf|7104 maintenance document]], p.30+ | |||
* [[T7101]] | |||
* [[Conrad Odenthal]], ''[[Media:Conrad Odenthal - A box-shaped scan expansion lens for an oscilloscope CRT.pdf|A box-shaped scan expansion lens for an oscilloscope CRT]] (1977) | |||
* [[Media:Box lens design being tried by Tektronix in experimental CRTs.pdf|Box lens design being tried by Tektronix in experimental CRTs]] (1977) | |||
{{PatentLinks|T7100}} | |||
==Screen shots | ==Pictures== | ||
<gallery> | |||
Tek 154-0783-00 1.jpg|154-0783-00 T7100 CRT | |||
Tek 154-0783-00 2.jpg|154-0783-00 T7100 CRT | |||
Tek t7100 internal1.JPG|T7100 internal | |||
Tek t7100 internal2.JPG|T7100 internal | |||
Tek t7100 internal3.JPG|T7100 internal | |||
Tek t7100 internal4.JPG|T7100 internal | |||
Tek t7100 internal5.JPG|T7100 internal | |||
Tek t7100 internal6.JPG|T7100 internal | |||
</gallery> | |||
'''Screen shots''' | |||
<gallery> | <gallery> | ||
Tek7104-200ps-singleshot.jpg | 7104 recording a single shot pulse (from [[067-0587-02]]) at 200 ps/Div. Camera: Nikon D7000, 50 mm f/1.4, ISO 3200, 1/2 s. CRT filter not removed. | |||
Tek7104-200ps-singleshot-sin1-1g.jpg | 7104 recording 1 GHz sine, single shot at 500 ps/Div. Camera: Nikon D7000, 50 mm f/1.4, ISO 3200, 1/2 s. CRT filter not removed. CRT amplification loss is evident around the center line. | |||
Tek t7100 lens structure.jpg | |||
</gallery> | </gallery> | ||
[[Category: | [[Category:Micro-channel plate CRTs]] |
Latest revision as of 03:52, 8 June 2024
The Tektronix T7100 (P/N 154-0783-00) is a micro-channel plate CRT used in the 7104 and R7103 analog 1 GHz scopes.
It features a micro-channel plate electron beam amplification stage.
Compared to non-MCP high-speed tubes, the T7100 uses reduced beam current and acceleration voltage to achieve high deflection sensitivity, eliminating the need for high amplifier output voltages, thereby boosting amplifier bandwidth.
The electron beam passes through terminated helical deflection plates (both X and Y axes use this form of distributed deflection plates to achieve the necessary bandwidth), followed by an electrostatic scan-expansion lens that increases deflection 4.5 times vertically and 4 times horizontally, before it hits the micro-channel plate (MCP). The deflection structures are described in US Patent 4,093,891. The scan-expansion lens is a "box lens" design, which is discussed on pages 53−55 of the 7104 maintenance document.
The MCP consists of parallel channels of 25 μm diameter and offset at a slight angle to the beam. The inside walls of these channels are coated with resistive material, with a voltage of 700-1050 V applied between back and front of the plate. Electrons entering a channel hit the wall where they initiate a cascade of secondary electron emission like in a photomultiplier.
A final 10 kV potential accelerates the beam across a 3 mm gap toward the phosphor coating.
The beam amplification is sufficient to view a single-shot event at 200 ps/Div with the naked eye.
The Micro-channel plate's amplification degrades irreversibly with operation, in proportion to the log of total charge passed per channel or display area. For this reason, continued operation with a steady trace and especially at large beam currents must be avoided. The 7104 contains a CRT protection circuit that shuts off the beam after a time depending on the beam current.
Key Specifications
Screen size | 8 × 10 Div. @ 8.5 mm |
---|---|
Resolution | 17 lines / Div. |
Vertical deflection factor | 1 V/cm |
Vertical deflection impedance | 200 Ω |
Vertical bandwidth | 2.6 GHz (3 GHz spec claimed in maintenance document linked below) |
Horizontal deflection factor | 2 V/Div |
Horizontal deflection impedance | 365 Ω |
Horizontal bandwidth | 1.5 GHz |
Links
- Hans Springer: Breakthroughs throughout push scope to 1 GHz
- 7104 maintenance document, p.30+
- T7101
- Conrad Odenthal, A box-shaped scan expansion lens for an oscilloscope CRT (1977)
- Box lens design being tried by Tektronix in experimental CRTs (1977)
Patents that may apply to T7100
Page | Title | Inventors | Filing date | Grant date | Links |
---|---|---|---|---|---|
Patent US 4142128A | Box-shaped scan expansion lens for cathode ray tube | Conrad Odenthal | 1977-04-18 | 1979-02-27 | T7100 • T7101 • 7104 • R7103 |
Pictures
-
154-0783-00 T7100 CRT
-
154-0783-00 T7100 CRT
-
T7100 internal
-
T7100 internal
-
T7100 internal
-
T7100 internal
-
T7100 internal
-
T7100 internal
Screen shots
-
7104 recording a single shot pulse (from 067-0587-02) at 200 ps/Div. Camera: Nikon D7000, 50 mm f/1.4, ISO 3200, 1/2 s. CRT filter not removed.
-
7104 recording 1 GHz sine, single shot at 500 ps/Div. Camera: Nikon D7000, 50 mm f/1.4, ISO 3200, 1/2 s. CRT filter not removed. CRT amplification loss is evident around the center line.
-