067-0532-01: Difference between revisions
Jump to navigation
Jump to search
(estimated introduction year = manual copyright year+1) |
No edit summary |
||
(2 intermediate revisions by 2 users not shown) | |||
Line 3: | Line 3: | ||
|model=067-0532-01 | |model=067-0532-01 | ||
|class=Signal generator | |class=Signal generator | ||
|summary=500 MHz Constant Amplitude Signal Generator | |summary=500 MHz Constant-Amplitude Signal Generator | ||
|image=067-0532-01 front.JPG | |image=067-0532-01 front.JPG | ||
|caption=Tektronix 067-0532-01 Constant Amplitude Signal Generator | |caption=Tektronix 067-0532-01 Constant Amplitude Signal Generator | ||
Line 10: | Line 10: | ||
|discontinued=(?) | |discontinued=(?) | ||
|manuals= | |manuals= | ||
* [[Media:062-1176-00.pdf|Tektronix 067-0532-01 Manual]] | * [[Media:062-1176-00.pdf|Tektronix 067-0532-01 Manual (062-1176-00)]] | ||
}} | }} | ||
The Tektronix '''Type 067-0532-01 Calibration Fixture''' is a constant amplitude signal generator whose output is a low-distortion sinewave. | The Tektronix '''Type 067-0532-01 Calibration Fixture''' is a constant amplitude signal generator whose output is a low-distortion sinewave. |
Latest revision as of 03:52, 12 June 2024
The Tektronix Type 067-0532-01 Calibration Fixture is a constant amplitude signal generator whose output is a low-distortion sinewave.
It is intended to provide a signal of known frequency and amplitude for measuring oscilloscope bandwidth.
A 3 MHz sinewave is available as a reference amplitude from which a –3 dB measurement can be made. The output connector, amplitude detector, and 50 Ω source resistor are situated at the end of a 42 inch cable. Output amplitude is regulated at the end of the cable adjacent to the GR-874 output connector, thus essentially eliminating cable loss and standing-wave errors.
Key Specifications
Frequency range | 65 MHz to 500 MHz |
---|---|
Frequency accuracy | ±2% of indicated frequency; 3 MHz output ±5% |
Amplitude range | 0.5 Vp-p to 4 Vp-p into 50 Ω in 0.5 Vp-p increments; variable between calibrated steps; max. output 4.2 Vp-p |
Amplitude accuracy | 3 MHz ±2%, 65−300 MHz ±2%, 300−500 MHz ±5% |
Output | 50 Ω ±1%, via GR-874 connector |
Pictures
-
Front view
-
Left side
-
Top internal
-
Bottom internal
-
Left internal
-
Right internal
-
Signal generator circuit
-
Line filter board