{{Oscilloscope Sidebar |
{{Oscilloscope Sidebar  
title=Tektronix 2465B |
|manufacturer=Tektronix
summary=Portable 200/250/400 MHz 4-ch scope |
|series=2400-series scopes
image=Tek 2455b trace.jpg |
|model=2465B  
caption=Tektronix 2465B |
|summary=Portable 200/250/400 MHz 4-ch scope  
introduced=1989 |
|image=Tek 2455b trace.jpg  
discontinued=(?) |
|caption=Tektronix 2465B  
manuals=
|introduced=1989  
* [[Media:070-6860-00.pdf|2445B/2455B/2465B Operator]]
|discontinued=(?)  
* [[Media:070-6861-00.pdf|2467B Operator -00]]
|designers=Art Metz;Ken Schlotzhauer;Walt Ainsworth
* [[Media:070-6861-01.pdf|2467B Operator -01]]
|manuals=
* [[Media:070-6861-02.pdf|2467B Operator -02]]
* [[Media:070-7148-00.pdf|070-7148-00 2445B/2465B/2467B Quick Start]]
* [[Media:070-6862-00.pdf|2445B/2455B Service]]
* [[Media:070-6860-00.pdf|070-6860-00 2445B/2455B/2465B Operator]]
* [[Media:070-6863-00.pdf|2465B/2467B Service -00]]
* [[Media:070-6861-00.pdf|070-6861-00 2467B Operator]] / [[Media:070-6861-01.pdf|-01]] / [[Media:070-6861-02.pdf|-02]]
* [[Media:070-6863-01.pdf|2465B/2467B Service -01]]
* [[Media:070-6862-00.pdf|070-6862-00 2445B/2455B Service]]
* [[Media:070-6864-02.pdf|2465B/2467B Options Service]]
* [[Media:070-6863-00.pdf|070-6863-00 2465B/2467B Service]] / [[Media:070-6863-01.pdf|-01]]
* [[Media:070-6882-00.pdf|2445B/2455B Service]]
* [[Media:070-6864-02.pdf|070-6864-02 2465B/2467B Options Service]] (SN B050000+)
* [[Media:070-7148-00.pdf|2445B/2465B/2467B Quick Start]]
 
{{ROM Images}}
}}
}}
 
The '''Tektronix 2465B''' is a four-channel 400 MHz portable oscilloscope.<br />
The '''Tektronix 2465B''' is a four-channel 400 MHz portable oscilloscope.  
The '''2445B''' and '''2455B''' are 200 and 250 MHz versions.<br />
The '''2445B''' and '''2455B''' are 200 and 250 MHz versions.
The '''2466B''' is a Sony/Tektronix model released in Japan, using a smaller CRT run at higher cathode voltage to give a brighter display to aid in photographing waveforms. It is not an MCP CRT.
 
CRT is the [[154-0850-01]].
CRT is the [[154-0850-01]].


The '''2466B''' is a 4-channel 400MHz Sony/Tektronix model released in Japan, using a smaller CRT run at higher cathode voltage to give a brighter display to aid in photographing waveforms. It is not an MCP CRT.<br />
The '''2467B''' is the same as the 2465B, except that the 2465B uses a conventional CRT while the 2467B uses a [[micro-channel plate CRT]]. The MCP CRT enables bright traces at fast sweep rates, particularly with one-shot or low repetition rate signals.
The '''2467B''' is the same as the 2465B, except that the 2465B uses a conventional CRT while the 2467B uses a [[micro-channel plate CRT]]. The MCP CRT enables bright traces at fast sweep rates, particularly with one-shot or low repetition rate signals.


Line 36: Line 35:
* Option 01 (DMM) added a 4½-digit, fully autoranging digital multimeter which measures DC and AC voltage and current, resistance, dBV, dBm, continuity, and temperature.
* Option 01 (DMM) added a 4½-digit, fully autoranging digital multimeter which measures DC and AC voltage and current, resistance, dBV, dBm, continuity, and temperature.
* Option 05 (TV) added TV (back-porch) clamp circuitry to the Channel 2 input and TV trigger coupling modes, allowing selection of either horizontal or vertical sync pulses to obtain horizontal-line-sync or field-sync pulse triggering.  
* Option 05 (TV) added TV (back-porch) clamp circuitry to the Channel 2 input and TV trigger coupling modes, allowing selection of either horizontal or vertical sync pulses to obtain horizontal-line-sync or field-sync pulse triggering.  
* Option 5H is a HDTV version of option 05.
* Option 06 (Counter/Timer/Trigger) allows precision time-interval measurement, event and frequency counting, delay-by-events triggering, and logic triggering.
* Option 06 (Counter/Timer/Trigger) allows precision time-interval measurement, event and frequency counting, delay-by-events triggering, and logic triggering.
* Option 09 added option 06, the CTT, plus a 17-bit [[P6407|P6407 word recognizer probe]].
* Option 09 added option 06, the CTT, plus a 17-bit [[P6407|P6407 word recognizer probe]].
* Option 10 added a [[GPIB interface]] for remote control.
* Option 10 added a [[GPIB interface]] for remote control.
* Option 11 added two [[LEMO S-series connector|probe-power connectors]] on the rear panel of the instrument.  Only shown in the 1989 catalogue.
* Option 11 added two [[LEMO S-series connector|probe-power connectors]] on the rear panel of the instrument.  Only shown in the 1989 catalogue.
* Option 22 indicates the scope was originally supplied with two extra probes.
* Option 46 is the designation for the military version of the scope (OS-288/G) that included option 10 IEEE-488 interface and 2 probes.
* Option 46 is the designation for the military version of the scope (OS-288/G) that included option 10 IEEE-488 interface and 2 probes.
* Option 1E Adds an External Frequency Reference (EFR) to Options 06 and 09 for increased accuracy.
* Option 1R is the 19" rack mount configuration.
'''Special Packages'''
* 2465BCT - [[GPIB interface]], Counter/Timer/Trigger, Word recognizer.
* 2465BDM - [[GPIB interface]], Counter/Timer/Trigger, Word recognizer, DMM.
* 2465BDV - [[GPIB interface]], Counter/Timer/Trigger, Word recognizer, DMM, Video trigger.


{{BeginSpecs}}
{{BeginSpecs}}
Line 54: Line 61:
{{Spec | Bandwidth | 400 MHz }}
{{Spec | Bandwidth | 400 MHz }}
{{SpecGroup|Common}}
{{SpecGroup|Common}}
{{Spec | Sweep Rate | 500 ps/div }}
{{Spec | Sweep Rate       | 500 ps/div }}
{{Spec | Channels | Four independent channels }}
{{Spec | Channels         | Four independent channels }}
{{Spec | Vertical | 2 mV/div vertical sensitivity }}
{{Spec | Vertical         | 2 mV/div vertical sensitivity }}
{{Spec | Cursors | Delta Volts and Delta Time Cursors }}
{{Spec | Cursors           | Delta Volts and Delta Time Cursors }}
{{Spec | CRT Readout | Scale Factors, Trigger Level, Voltage, Time, Frequency, Phase and Ratio Measurements and Mode Indicators }}
{{Spec | CRT Readout       | Scale Factors, Trigger Level, Voltage, Time, Frequency, Phase and Ratio Measurements and Mode Indicators }}
{{Spec | Trigger | Advanced Triggering with "Hands Off" Auto Level Triggering }}
{{Spec | Trigger           | Advanced Triggering with "Hands Off" Auto Level Triggering }}
{{Spec | Trigger Bandwidth | 500 MHz min. }}
{{Spec | Trigger Bandwidth | 500 MHz min. }}
{{Spec | Input Impedance| 50 Ω/1 MΩ inputs with 50 Ω protection }}
{{Spec | Input Impedance   | 50 Ω/1 MΩ inputs with 50 Ω protection }}
{{Spec | Probes | Two or four [[P6137]] ×10 probes, 1.3 m  }}
{{Spec | Probes           | Two or four [[P6137]] ×10 probes, 1.3 m  }}
{{EndSpecs}}
{{EndSpecs}}


==Prices==
==Prices==
1990: $13,045 (2467B) = $24,400 equivalent in 2017
1990: $13,045 (2467B) = $30,300 equivalent in 2023


==See also==
==See also==
Line 82: Line 89:


==Pictures==
==Pictures==
===2445B===
<gallery>
Tek_2445B-Trace.jpeg  | Trace
Tek_2445B_Front.jpeg  | Front
Tek_2445B_Rear.jpeg  | Back
Tek_2445B-Top.jpeg    | Internals - Top
Tek_2445B-Bottom.jpeg | Internals - Bottom
Tek_2445B-RHS.jpeg    | Internals - RHS
Tek_2445B-LHS.jpeg    | Internals - LHS
</gallery>
===2455B===
===2455B===
<gallery>
<gallery>
Line 89: Line 108:
===2465B===
===2465B===
<gallery>
<gallery>
Tek 2465b trace1.jpg |2465B (photo by Alex Schonfeld)
Tek 2465b trace1.jpg                   |2465B (photo by Alex Schonfeld)
Tek 2465b trace2.jpg |2465B (photo by Alex Schonfeld)
Tek 2465b trace2.jpg                   |2465B (photo by Alex Schonfeld)
Tek 2465b trace3.jpg |2465B (photo by Alex Schonfeld)
Tek 2465b trace3.jpg                   |2465B (photo by Alex Schonfeld)
Tek 2465b trace4.jpg |2465B (photo by Alex Schonfeld)
Tek 2465b trace4.jpg                   |2465B (photo by Alex Schonfeld)
Tek 2465b trace5.jpg |2465B (photo by Alex Schonfeld)
Tek 2465b trace5.jpg                   |2465B (photo by Alex Schonfeld)
2465B_Opt-2_Probe_Power_Rear.jpg      |Opt.11 Probe Power
2465B_Opt-2_Probe_Power_Inside.jpg    |Opt.11 Top with RIFA cap debris
2465B_Opt-2_Probe_Power_Inside-Top.jpg |Opt.11 Inside with RIFA cap debris
</gallery>
</gallery>


===2465BDM===
<gallery>
Tek_2465BDM_3.jpeg | 2465BDM
Tek_2465BDM_4.jpeg | 2465BDM
Tek_2465BDM_2.jpeg | 2465BDM
Tek_2465BDM_1.jpeg | 2465BDM
</gallery>
===2465BDV===
===2465BDV===
<gallery>
<gallery>
Line 113: Line 142:
Tek_2467B.jpg
Tek_2467B.jpg
</gallery>
</gallery>
==Components==
{{Parts|2445B}}
{{Parts|2455B}}
{{Parts|2465B}}
{{Parts|2466B}}
{{Parts|2467B}}




[[Category:246x series scopes]]
[[Category:246x series scopes]]
[[Category:Introduced in 1989]]
[[Category:Introduced in 1989]]