2465: Difference between revisions

360 bytes removed ,  14 June
no edit summary
No edit summary
No edit summary
(12 intermediate revisions by 3 users not shown)
Line 12: Line 12:
'''2445'''
'''2445'''
* [[Media:070-3830-00.pdf|2445 Operator]] (OCR, 17M)
* [[Media:070-3830-00.pdf|2445 Operator]] (OCR, 17M)
* [[Media:070-3829-00.pdf|2445 Service]] (OCR, 27M)
* [[Media:070-3829-00.pdf|2445 Service, January 1983 Edition]] (OCR, 27M)
'''2465'''
'''2465'''
* [[Media:070-3832-00.pdf|070-3832-00 2465 Operator]] (OCR, 22M)
* [[Media:070-3832-00.pdf|070-3832-00 2465 Operator]] (OCR, 22M)
* [[Media:070-3831-00.pdf|070-3831-00 2465 Service]] (29M) / [[Media:070-3831-00_plus_chg.pdf|070-3831-00 + changes]] (OCR, 20M)
* [[Media:070-3831-00.pdf|070-3831-00 2465 Service]] (29M) / [[Media:070-3831-00_plus_chg.pdf|070-3831-00 + changes]] (OCR, 20M)
'''Common'''
'''Common'''
* [[Media:070-6863-01.pdf|Tektronix 2465B & 2467B Service Manual]]
* [[Media:070-4180-00.pdf|2445/2465 Quick Start]] (OCR, 2.5M)
* [[Media:070-4180-00.pdf|2445/2465 Quick Start]] (OCR, 2.5M)
* [[Media:070-4182-00.pdf|Opt.01 DMM Service]] (OCR, 11M)
* [[Media:070-4182-00.pdf|Opt.01 DMM Service]] (OCR, 11M)
Line 27: Line 28:
* [[Media:070-4633-00.pdf|Opt.10 GPIB Operator]] (OCR, 9M)
* [[Media:070-4633-00.pdf|Opt.10 GPIB Operator]] (OCR, 9M)
* [[Media:070-4640-00.pdf|Opt.10 GPIB Service]] (OCR, 23M)
* [[Media:070-4640-00.pdf|Opt.10 GPIB Service]] (OCR, 23M)
* [[Media:070-6291-00.pdf|Tektronix 2445/2465/2467 Buffer Test Kit]] (needs OCR)
* [[Media:070-5150-00.pdf|Opt.10 Instrument Interfacing Guide]]
* [[Media:070-6291-00.pdf|Tektronix 2445/2465/2467 Buffer Test Kit]]


{{ROM Images}}
{{ROM Images}}
* A4U2931:  [[Media:160-1631-02.bin|160-1631-02]]
* A5U2162:  [[Media:160-1994-11.bin|160-1994-11]] / [[Media:160-1994-09.bin|-09]]
* A5U2178:  [[Media:160-1625-11.bin|160-1625-11]] / [[Media:160-1625-07.bin|-07]] / [[Media:160-1625-06.bin|-06]] / [[Media:160-1625-04.bin|-04]]
* A5U2378:  [[Media:160-1995-11.bin|160-1995-11]] / [[Media:160-1995-09.bin|-09]]<br /> [[Media:160-1626-11.bin|160-1626-11]] / [[Media:160-1626-07.bin|-07]] / [[Media:160-1626-06.bin|-06]] / [[Media:160-1626-04.bin|-04]]
* A5U2362:  [[Media:160-1627-11.bin|160-1627-11]] / [[Media:160-1627-07.bin|-07]] / [[Media:160-1627-06.bin|-06]] / [[Media:160-1627-04.bin|-04]]
* A5U2162:  [[Media:160-1628-11.bin|160-1628-11]] / [[Media:160-1628-07.bin|-07]] / [[Media:160-1628-06.bin|-06]] / [[Media:160-1628-04.bin|-04]]
* A20U4260: [[Media:160-1833-06.bin|160-1833-06]]
* A23U4710: [[Media:160-1681-14.bin|160-1681-14]]
* A23U4715: [[Media:160-1692-15.bin|160-1692-15]] / [[Media:160-1692-14.bin|-14]]
* A27U5930: [[Media:160-2298-04.bin|160-2298-04]]
}}
}}
The '''Tektronix 2465''' is a four-channel 300 MHz portable oscilloscope from the penultimate generation of analog Tektronix scopes.  The '''2445''' is a 150 MHz version.  ''See [[2465A]] and [[2465B]] for the successor versions.''
The '''Tektronix 2465''' is a four-channel 300 MHz portable oscilloscope from the penultimate generation of analog Tektronix scopes.  The '''2445''' is a 150 MHz version.  ''See [[2465A]] and [[2465B]] for the successor versions.''
Line 51: Line 43:
'''Options'''
'''Options'''
* Option 01 (DMM) added a 4½-digit, fully autoranging digital multimeter which measures DC and AC voltage and current, resistance, dBV, dBm, continuity, and temperature.
* Option 01 (DMM) added a 4½-digit, fully autoranging digital multimeter which measures DC and AC voltage and current, resistance, dBV, dBm, continuity, and temperature.
* Option 05 (TV) added TV (back-porch) clamp circuitry to the Channel 2 input and TV trigger coupling modes, allowing selection of either horizontal or vertical sync pulses to obtain horizontal-line-sync or field-sync pulse triggering.  
* Option 05 (TV) added TV (back-porch) clamp circuitry to the Channel 2 input and TV trigger coupling modes, allowing selection of either horizontal or vertical sync pulses to obtain horizontal-line-sync or field-sync pulse triggering. A knob and an on-screen numerical display allows selection of a line number to be displayed. If the scope is in mixed time base mode, an intensified region is shown in the field rate display.
* Option 06 (Counter/Timer/Trigger) allows precision time-interval measurement, event and frequency counting, delay-by-events triggering, and logic triggering.
* Option 06 (Counter/Timer/Trigger) allows precision time-interval measurement, event and frequency counting, delay-by-events triggering, and logic triggering.
* Option 09 added option 06, the CTT, plus a 17-bit [[P6407|P6407 word recognizer probe]].
* Option 09 added option 06, the CTT, plus a 17-bit [[P6407|P6407 word recognizer probe]].
Line 78: Line 70:
* [https://hackaday.io/project/163890-tektronix-2465-series-servicing 2465 series servicing] @ hackaday.io
* [https://hackaday.io/project/163890-tektronix-2465-series-servicing 2465 series servicing] @ hackaday.io
* [https://www.youtube.com/watch?v=Rks_AyfJNq4 Tektronix 2445 Oscilloscope Repair] by NFM @ YouTube
* [https://www.youtube.com/watch?v=Rks_AyfJNq4 Tektronix 2445 Oscilloscope Repair] by NFM @ YouTube
==Prices==
'''2465'''
{| class="wikitable"
|-
! Year
! 1984
! 1986
|-
! Catalog Price
|align=right|
|align=right| $5,350
|-
! In 2023 Dollars
|align=right|
|align=right| $15,000
|}
'''2445'''
{| class="wikitable"
|-
! Year
! 1984
! 1986
|-
! Catalog Price
|align=right|
|align=right| $3,590
|-
! In 2023 Dollars
|align=right|
|align=right| $10,100
|}


==Pictures==
==Pictures==
Line 100: Line 125:
</gallery>
</gallery>


{{CRTs|2445}}
==Components==
{{CRTs|2465}}
{{Parts|2445}}
 
{{Parts|2465}}
{{Custom ICs|2445}}
{{Custom ICs|2465}}