{{Instrument Sidebar | |||
|manufacturer=Tektronix | |||
|model=414 | |||
|class=Medical | |||
|series= | |||
|summary=Portable Patient Monitor | |||
|image=Tek 400 1.jpg | |||
|caption=Tektronix 414 Portable Patient Monitor | |||
|introduced=1976 | |||
|discontinued=(?) | |||
|designers= | |||
|manuals= | |||
* [https://archive.org/download/070-2042-01/070-2042-01.pdf Tektronix 414 Monitor with Options Manual] | |||
* [[Media:070-2041-00.pdf|Tektronix 414 Operators Manual]] | |||
* [[Media:070-2857-01.pdf|Tektronix 400 Series System Calibration]] | |||
}} | |||
[[File:414.jpg|thumb|400px|right]] | [[File:414.jpg|thumb|400px|right]] | ||
The '''Tektronix 414 Portable Patient Monitor''' is a dual-trace instrument that | The '''Tektronix 414 Portable Patient Monitor''' is a dual-trace instrument that simultaneously displays ECG and blood pressure or peripheral pulse, | ||
simultaneously displays ECG and blood pressure or peripheral pulse, | |||
and provides a digital readout of heart rate, respiration rate, systolic/diastolic blood pressure, or temperature. | and provides a digital readout of heart rate, respiration rate, systolic/diastolic blood pressure, or temperature. | ||
It has pressure and heart rate alarms with selectable limits. | It has pressure and heart rate alarms with selectable limits. | ||
It is AC or battery operated. | It is AC or battery operated. | ||
It can be used with the [[400]] strip chart recorder. | It can be used with the [[400]] strip chart recorder. | ||
Option 21 | {{MissingSpecs}} | ||
<small> | |||
'''Options''' | |||
* Option 2: EXTERNAL PRESSURE GAUGE-FACTOR ADJUSTMENT: Pressure Gauge Factor control added to rear panel to accommodate non- standard transducers. | |||
* Option 3: F-CELL BATTERY PACK: F-Cell battery pack provided in place of D-Cell pack. | |||
* Option 4: ECG FULL-LEAD SELECTION: Provides an 8-position rotary switch in place of the 3 ECG lead selector pushbuttons. | |||
* Option 10: ELECTRO-SURGICAL INTERFERENCE SUPPRESSION: Specially designed ECG circuit enhances interpretation of the ECG waveform when electro-surgical instruments are used. | |||
* Option 15: NO ACCESSORIES: Deletes all included accessories except manuals. | |||
* Option 20: NO PRESSURE: Deletes blood pressure facilities leaving dual-trace capability of ECG and pulse. | |||
* Option 21: DUAL PRESSURE: Provides a second pressure channel in place of the pulse channel in the standard 414 Monitor. | |||
</small> | |||
==Links== | ==Links== | ||
* [[Media:1976 Tektronix Catalog.pdf|1976 Tektronix Catalog, p.197+]] | |||
* [https://vintagetek.org/medical-products/ Medical Products] @ vintagetek.org | |||
{{Documents|Link=414}} | |||
{{PatentLinks|414}} | |||
* [ | ==See Also== | ||
* [[067-0706-99]] Medical Monitor Test Unit | |||
==Pictures== | |||
<gallery> | <gallery> | ||
Tek 400 1.jpg | Tek 400 1.jpg | ||
Line 18: | Line 50: | ||
Tek 400 3.jpg | Tek 400 3.jpg | ||
Tek 400 4.jpg | Tek 400 4.jpg | ||
Tek 414 1.jpg | |||
Tek 414 2.jpg | |||
Tek 414 3.jpg | |||
Tek 414 4.jpg | |||
Tek 414 5.jpg | |||
Tek 414 6.jpg | |||
Tek 414 7.jpg | |||
Tek 414 8.jpg | |||
Tek 414 9.jpg | |||
Tek 414 trace.jpg|414 trace | |||
</gallery> | </gallery> | ||
[[Category:Healthcare products]] | [[Category:Healthcare products]] | ||
[[Category:Special-purpose oscilloscopes]] | [[Category:Special-purpose oscilloscopes]] | ||
{{MissingSpecs}} | {{MissingSpecs}} |