PG505: Difference between revisions

no edit summary
No edit summary
No edit summary
Line 2: Line 2:
|mfg=Tektronix  
|mfg=Tektronix  
|type=PG505  
|type=PG505  
|function=1 Hz − 100 kHz high-voltage pulse generator  
|function=100 kHz, 80 V pulse generator  
|class=pulse generator  
|class=pulse generator  
|image=Tek_pg505_front1.jpg  
|image=Tek_pg505_front1.jpg  
Line 33: Line 33:
==Operation==
==Operation==
The main controls are a pair of concentric switches for pulse period and pulse duration, with the latter mechanically limited to prevent the duration range to be set higher than the period range.
The main controls are a pair of concentric switches for pulse period and pulse duration, with the latter mechanically limited to prevent the duration range to be set higher than the period range.
When period and duration switches are in the same position and the variable controls set ×1 (ccw) the output runs at 50% duty cycle.


In the leftmost position of the duration switch, the output is locked in its "on" state so that the amplitude can be set conveniently with a DC voltmeter attached to the output.
In the leftmost position of the duration switch, the output is locked in its "on" state so that the amplitude can be set conveniently with a DC voltmeter attached to the output.
Line 43: Line 44:
When the ramp reaches the threshold, an output pulse of the set duration is triggered.
When the ramp reaches the threshold, an output pulse of the set duration is triggered.


When the duration switch is put in the rightmost position (which mechanically forces the period switch to the same), both the rate and duration generator circuits are disabled.
When the duration switch is put in the rightmost position as well (which mechanically forces the period switch to the same), both the rate and duration generator circuits are disabled.
In this "EXT DURATION" mode, the output simply follows the Delay/Ext Duration input  
In this "EXT DURATION" mode, the output simply follows the Delay/Ext Duration input as compared to the threshold set by the variable delay potentiometer (0−10 V).


==Rear Interface==
==Rear Interface==