P6011: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
(10 intermediate revisions by 4 users not shown) | |||
Line 1: | Line 1: | ||
The '''Tektronix P6011''' is a passive ×1 probe with a BNC connector. | {{Probe Sidebar | ||
|manufacturer=Tektronix | |||
|model=P6011 | |||
|summary=Passive ×1 Probe | |||
|image=Tek p6011 1.jpg | |||
|caption=P6011 | |||
|for=1 MΩ scope inputs | |||
|introduced=(?) | |||
|discontinued=(?) | |||
|designers= | |||
|manuals= | |||
* [[Media:070-0512-01.pdf|Tektronix P6011 Manual]] | |||
* [[Media:070-0726-00.pdf|P6011 Manual, German]] (OCR) | |||
}} | |||
The '''Tektronix P6011''' is a passive ×1 probe with a [[BNC]] connector. | |||
It has a small diameter probe body, making it more useful in crowded circuitry. | |||
The probe came in three lengths: 3.5 ft. (010-0192-00), 6 ft. (010-0189-00), and 9 ft. (010-0228-00). | |||
{{BeginSpecs}} | |||
{{Spec | Attenuation | ×1 }} | |||
{{Spec | Maximum Voltage | 600 V (DC + peak AC), derated with frequency }} | |||
{{Spec | Input Capacitance | 28−75 pF, depending on cable length }} | |||
{{Spec | Rise Time | 12−25 ns, depending on cable length, and instrument input capacitance }} | |||
{{EndSpecs}} | |||
==Pictures== | ==Pictures== | ||
Line 13: | Line 33: | ||
[[Category:1 | [[Category:1 MΩ Oscilloscope probes]] |
Latest revision as of 16:30, 9 March 2024
The Tektronix P6011 is a passive ×1 probe with a BNC connector. It has a small diameter probe body, making it more useful in crowded circuitry. The probe came in three lengths: 3.5 ft. (010-0192-00), 6 ft. (010-0189-00), and 9 ft. (010-0228-00).
Key Specifications
Attenuation | ×1 |
---|---|
Maximum Voltage | 600 V (DC + peak AC), derated with frequency |
Input Capacitance | 28−75 pF, depending on cable length |
Rise Time | 12−25 ns, depending on cable length, and instrument input capacitance |