P6129: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(6 intermediate revisions by 2 users not shown)
Line 1: Line 1:
* [[Media:070-8547-05.pdf|Tektronix P6129B Manual (PDF)]]
{{Probe Sidebar
|manufacturer=Tektronix
|model=P6129
|summary=100 MHz, ×1/×10 passive probe
|image=Tek p6129b 1.jpg
|caption=P6129B
|for=1 MΩ scope inputs
|introduced=1991
|discontinued=(?)
|manuals=
* [[Media:070-8279-00.pdf|Tektronix P6129 Manual]] ''needed''
* [[Media:070-8547-05.pdf|Tektronix P6129B Manual]]
}}
The '''Tektronix P6129''' is a passive 100 MHz ×1/×10 [[miniature modular probe]], with a [[BNC connector]] that has a [[readout pin]].


{{BeginSpecs}}
{{Spec|Attenuation          | ×1/×10 ±1.35% at DC }}
{{Spec|Input Impedance      | ×1: 1 MΩ ±1.0% // 90–115 pF; ×10: 10 MΩ ±1.3% // 18.5 pF (17.5–19.5 pF) }}
{{Spec|Compensation Range    | 15–35 pF }}
{{Spec|Bandwidth            | ×1: DC–10 MHz; ×10: DC–100 MHz }}
{{Spec|Maximum Input Voltage | 420 V (DC + peak AC) nondestructive }}
{{EndSpecs}}
==Pictures==
<gallery>
<gallery>
Tek p6129b 1.jpg
Tek p6129b 1.jpg
Line 6: Line 28:
Tek p6129b 3.jpg
Tek p6129b 3.jpg
Tek p6129b 4.jpg
Tek p6129b 4.jpg
Tek p6129 in package 1.jpg
Tek p6129 in package 2.jpg
</gallery>
</gallery>
[[Category:1 MΩ Oscilloscope probes]]
[[Category:Miniature modular probes]]

Latest revision as of 04:10, 18 July 2024

Tektronix P6129
100 MHz, ×1/×10 passive probe
P6129B

Compatible with 1 MΩ scope inputs

Produced from 1991 to (?)

Manuals


Manuals – Specifications – Links – Pictures

The Tektronix P6129 is a passive 100 MHz ×1/×10 miniature modular probe, with a BNC connector that has a readout pin.

Key Specifications

Attenuation ×1/×10 ±1.35% at DC
Input Impedance ×1: 1 MΩ ±1.0% // 90–115 pF; ×10: 10 MΩ ±1.3% // 18.5 pF (17.5–19.5 pF)
Compensation Range 15–35 pF
Bandwidth  ×1: DC–10 MHz; ×10: DC–100 MHz
Maximum Input Voltage 420 V (DC + peak AC) nondestructive

Pictures