2201: Difference between revisions
Jump to navigation
Jump to search
Blunite5454 (talk | contribs) No edit summary |
No edit summary |
||
(8 intermediate revisions by 4 users not shown) | |||
Line 1: | Line 1: | ||
{{Oscilloscope Sidebar| | {{Oscilloscope Sidebar | ||
|manufacturer=Tektronix | |||
image=Tek 2201 trace.jpg | | |series=2200-series scopes | ||
caption=Tektronix 2201 | | |model=2201 | ||
introduced=1988 | | |image=Tek 2201 trace.jpg | ||
discontinued=1993 | | |caption=Tektronix 2201 | ||
summary=10 MHz, 20 MS/s analog/digital scope | | |introduced=1988 | ||
manuals= | |discontinued=1993 | ||
* [ | |summary=10 MHz, 20 MS/s analog/digital scope | ||
|designers= | |||
|manuals= | |||
* [[Media:070-7189-00.pdf|Tektronix 2201 Service Manual]] | |||
* [https://w140.com/Tek2201_description.pdf Tektronix 2201 Description] | |||
* [[Media:2201Scematics.pdf | Partial schematic (delay line driver, vertical output amplifier, power supply, HV and CRT circuits)]] | * [[Media:2201Scematics.pdf | Partial schematic (delay line driver, vertical output amplifier, power supply, HV and CRT circuits)]] | ||
* | * [https://w140.com/tekwiki/images/4/48/070-7232-00.pdf Tektronix 2201 Reference Guide] | ||
}} | }} | ||
The '''Tektronix 2201''' is a combined 10 MHz | The '''Tektronix 2201''' is a combined 10 MHz, 20 MS/s analog/digital oscilloscope [[introduced in 1988]]. | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Rise time | 17.5 ns }} | {{Spec | Rise time | 17.5 ns }} | ||
{{Spec | Bandwidth | 20 MHz (analog) }} | {{Spec | Bandwidth | 20 MHz (analog) }} | ||
{{Spec | Deflection | 5 mV/Div to 5 V/Div, 1-2-5, ±3% }} | {{Spec | Deflection | 5 mV/Div to 5 V/Div, 1-2-5, ±3% }} | ||
{{Spec | Sweep (analog) | 50 ns/Div to 0.5 s/Div, ×10 magnifier (5 ns/Div) }} | {{Spec | Sweep (analog) | 50 ns/Div to 0.5 s/Div, ×10 magnifier (5 ns/Div) }} | ||
{{Spec | Sweep (digital) | 20 μs/Div to 0.5 s/Div, ×100 store to 50 s/Div | {{Spec | Sweep (digital) | 20 μs/Div to 0.5 s/Div, ×100 store to 50 s/Div }} | ||
{{Spec | Input impedance | 1 MΩ // 25 pF }} | {{Spec | Input impedance | 1 MΩ // 25 pF }} | ||
{{Spec | Sampling rate | 10 MS/s, both channels simultaneously (two ADCs) }} | {{Spec | Sampling rate | 10 MS/s, both channels simultaneously (two ADCs) }} | ||
{{Spec | Record length | 2K per channel }} | {{Spec | Record length | 2K per channel }} | ||
{{Spec | Resolution | vertical 8 bit, horizontal 11 bit }} | {{Spec | Resolution | vertical 8 bit, horizontal 11 bit }} | ||
{{Spec | Probes | Two P6103 | {{Spec | Probes | Two [[P6103]] ×10, 2 m Probes }} | ||
{{Spec | CRT | 8 cm × 10 cm, 12.5 kV acceleration }} | {{Spec | CRT | 8 cm × 10 cm, 12.5 kV acceleration }} | ||
{{Spec | Power | 95−128 V<sub>AC</sub> / 185−250 V<sub>AC</sub>, 48−440 Hz, 70 W }} | {{Spec | Power | 95−128 V<sub>AC</sub> / 185−250 V<sub>AC</sub>, 48−440 Hz, 70 W }} | ||
{{Spec | Size and weight | 138 mm (w) × 380 mm (h) × 438 mm (d), 7.6 kg }} | {{Spec | Size and weight | 138 mm (w) × 380 mm (h) × 438 mm (d), 7.6 kg }} | ||
{{Spec | Features | | {{Spec | Features | | ||
* Readout | * Readout | ||
* Cursors | * Cursors | ||
Line 33: | Line 37: | ||
* X-Y operation (2 MHz X BW), ±3° from DC to 50 kHz | * X-Y operation (2 MHz X BW), ±3° from DC to 50 kHz | ||
* One trace reference memory | * One trace reference memory | ||
* RS-232 interface (option 12) with hardcopy function (HPGL, Epson FX) | * [[RS-232 interface]] (option 12) with hardcopy function (HPGL, Epson FX) | ||
}} | }} | ||
{{EndSpecs}} | {{EndSpecs}} | ||
Line 53: | Line 57: | ||
Tek 2201 e2.jpg | Tek 2201 e2.jpg | ||
</gallery> | </gallery> | ||
==Components== | |||
{{Parts|2201}} | |||
[[Category:Digital storage scopes]] | [[Category:Digital storage scopes]] | ||
[[Category:2200 series scopes]] | [[Category:2200 series scopes]] |
Latest revision as of 00:20, 10 October 2023
The Tektronix 2201 is a combined 10 MHz, 20 MS/s analog/digital oscilloscope introduced in 1988.
Key Specifications
Rise time | 17.5 ns |
---|---|
Bandwidth | 20 MHz (analog) |
Deflection | 5 mV/Div to 5 V/Div, 1-2-5, ±3% |
Sweep (analog) | 50 ns/Div to 0.5 s/Div, ×10 magnifier (5 ns/Div) |
Sweep (digital) | 20 μs/Div to 0.5 s/Div, ×100 store to 50 s/Div |
Input impedance | 1 MΩ // 25 pF |
Sampling rate | 10 MS/s, both channels simultaneously (two ADCs) |
Record length | 2K per channel |
Resolution | vertical 8 bit, horizontal 11 bit |
Probes | Two P6103 ×10, 2 m Probes |
CRT | 8 cm × 10 cm, 12.5 kV acceleration |
Power | 95−128 VAC / 185−250 VAC, 48−440 Hz, 70 W |
Size and weight | 138 mm (w) × 380 mm (h) × 438 mm (d), 7.6 kg |
Features |
|
Links
- 2201 Repair part 1 / part 2 / part 3 / part 4 @ YouTube
Pictures
Components
Some Parts Used in the 2201
- (no results)