2622: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(18 intermediate revisions by 4 users not shown)
Line 1: Line 1:
{{Oscilloscope Sidebar |
{{Instrument Sidebar  
title=Tektronix 2622 |
|manufacturer=Tektronix
summary=Fourier Analyzer DC to 20 kHz |
|model=2622  
image= Tek 2622.jpg |
|class=Spectrum Analyzer
caption=Tektronix 2622 |
|summary=20 kHz Fourier Analyzer
introduced=1990 |
|image=Tek 2622.jpg  
discontinued=1995 |
|caption=Tektronix 2622  
manuals=
|introduced=1990  
Need User Guide and Service Manual
|discontinued=1995  
* [[Media:Tek_2600_Series_Catalog_1990.pdf| Tektronix 2622 Introduction Spec (PDF)]]
|manuals=
* [[Media:Tek_2600_Series_Catalog_1994.pdf| Tektronix 2622 Final Spec (PDF)]]
* [[Media:Tek_2600_Series_Catalog_1990.pdf| Tektronix 2622 Introduction Spec]]
* [[Media:Tek_2600_Series_Catalog_1994.pdf| Tektronix 2622 Final Spec]]
* ''User Guide and Service Manual needed'' [[Category:Manual needed]]
}}
}}
 
The '''Tektronix 2622''' is a Fourier analyzer that links dedicated signal acquisition and analysis with a personal computer’s mass storage and graphics.  It allows measurement solutions for electrical, mechanical, and electromechanical applications in the DC to 20 kHz frequency range.  Typical applications are Structural Analysis, Control Systems, Machine Vibration, Audio and Acoustic Tests, and General Purpose Signal and System Analysis.
The '''Tektronix 2622''' is a Fourier analyzer links dedicated signal acquisition and analysis with a personal computer’s mass storage and graphics.  It allows measurement solutions for electrical, mechanical, and electromechanical applications in the DC to 20 kHz frequency range.  Typical applications are Structural Analysis, Control Systems, Machine Vibration, Audio and Acoustic Tests, and General Purpose Signal and System Analysis.


Each of the channel inputs provide simultaneous sampling of all channels utilizing 12 bit ADC standard or 16 bit ADC optionally.  Signal processing includes Fourier Transform (FFT) and Spectral Lines.  The signal generator has a wide variety of functions, like sine, square, sawtooth, triangle, input, random, adjustable random, chirp, and arbitrary.  With the optional TurboPac Application Library and Run-Time License advanced measurement calculations and graphs can be generated from the data collected.
Each of the channel inputs provide simultaneous sampling of all channels utilizing 12 bit ADC standard or 16 bit ADC optionally.  Signal processing includes Fourier Transform (FFT) and Spectral Lines.  The signal generator has a wide variety of functions, like sine, square, sawtooth, triangle, input, random, adjustable random, chirp, and arbitrary.  With the optional TurboPac Application Library and Run-Time License advanced measurement calculations and graphs can be generated from the data collected.
Line 18: Line 19:
The PC’s monitor displays the measurements results – but that’s where the Fourier Analyzer dependence on the PC stops.  All of the data acquisition, data management, signal processing and other computationally intensive operations are reserved for the Fourier Analyzer’s high-performance measurement and analysis hardware.  Built-in analog and digital anti-alias filters automatically track all of the bandwidth settings.  A selection of frame sizes allows the user to choose the best trade-off between acquisition time and frequency resolution.  When high frequency resolution around a specific signal is needed, the option "zoom" feature can be used.  It allows one to focus up to 800 spectral line with a span as small as 10 Hz about the frequency of interest.
The PC’s monitor displays the measurements results – but that’s where the Fourier Analyzer dependence on the PC stops.  All of the data acquisition, data management, signal processing and other computationally intensive operations are reserved for the Fourier Analyzer’s high-performance measurement and analysis hardware.  Built-in analog and digital anti-alias filters automatically track all of the bandwidth settings.  A selection of frame sizes allows the user to choose the best trade-off between acquisition time and frequency resolution.  When high frequency resolution around a specific signal is needed, the option "zoom" feature can be used.  It allows one to focus up to 800 spectral line with a span as small as 10 Hz about the frequency of interest.


'''[[wikipedia:Fast_Fourier_transform|Fast Fourier transform]]''' is an algorithm that computes the [[wikipedia:Discrete_Fourier_transform|descrete Fourier transform]] (DFT) of a sequence, or its inverse (IDFT). [[Wikipedia:Fourier_analysis|Fourier analysis]] converts a signal from its original domain (often time or space) to a representation in the [[Wikipedia:Frequency_domain|frequency domain]] and vice versa..
To learn more about FFT read '''[[wikipedia:Fast_Fourier_transform|Fast Fourier transform]]''' on at https://en.wikipedia.org/wiki/Fast_Fourier_transform.
[[File:FFT_of_Cosine_Summation_Function.png|center|500px|Fourier analysis]]


Front panel inputs/outputs are: CH1 and CH2 each with a [[BNC connector]] (1 MΩ; 200 pF; ±30 V); OUTPUT [[BNC connector]] (50Ω; ±10 V; signal general output capable of a variety of pre-defined, as well as user-defined, signals.)
Front panel inputs/outputs are: CH1 and CH2 each with a [[BNC connector]] (1 MΩ; 200 pF; ±30 V); and OUTPUT [[BNC connector]] (50Ω; ±10 V; signal general output capable of a variety of pre-defined, as well as user-defined, signals.)


Rear panel inputs/outputs are: SYSTEM INTERCONNECT [[DB9 connector]] (Male connector used for both External triggering, and External sampling inputs.  All pins TTL-level except Signal ground: Pin 1 triggering signal input; pin 2 trigger sense output; pin 3 external clock input; pins 6 thru 8 signal ground; pin 9 is the external sampling input); SERIAL PORT [[BNC connector]] (Female connector used linking to the host computer via a Tektronix supplied serial interface cable).
Rear panel inputs/outputs are: SYSTEM INTERCONNECT [[DB9 connector]] (Male connector used for both External triggering, and External sampling inputs.  All pins TTL-level except Signal ground: Pin 1 triggering signal input; pin 2 trigger sense output; pin 3 external clock input; pins 6 thru 8 signal ground; pin 9 is the external sampling input); and SERIAL PORT [[BNC connector]] (Female connector used linking to the host computer via a Tektronix supplied serial interface cable).


---------------------------------------------------------
---------------------------------------------------------
<div style='text-align: center;'>Specifications based on 2000 published documentation, unless otherwise specified.</div>
<div style='text-align: center;'>Specifications based on 1994 published documentation, unless otherwise specified.</div>
{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | Frequency Ranges | DC to 20 kHz }}
{{Spec | Frequency Ranges | DC to 20 kHz }}
Line 39: Line 38:
{{Spec | Input Impedance | 1 MΩ; 200 pF }}
{{Spec | Input Impedance | 1 MΩ; 200 pF }}
{{Spec | Max Input Level | ±30 V }}
{{Spec | Max Input Level | ±30 V }}
{{Spec | Included Accessories | User Guide; Instrument Program Software; System Simulator Box; Power Cord; and Serial Interface Cable (please specify) }}
{{Spec | Included Accessories | User Guide; Instrument Program Software; [[System Simulator]] Box; Power Cord; and Serial Interface Cable (please specify) }}
{{Spec | Weight | Standard accessories: 3.8 kg (8.5 lbs) }}
{{Spec | Weight | Standard accessories: 5.5 kg (12 lbs) }}
{{Spec | Power | 90 − 250 V<sub>AC</sub>, 48 to 66 Hz, >120 W }}
{{Spec | Power | 90 − 250 V<sub>AC</sub>, 48 to 66 Hz, >120 W }}
{{Spec | Operating Atmospherics | Temperatures: 0 °C to +50 °C; Humidity: 95% for five days; Altitude: Up to 4.8 km (15,000 ft) }}
{{Spec | Operating Atmospherics | Temperatures: 0 °C to +50 °C; Humidity: 95% for five days; Altitude: Up to 4.8 km (15,000 ft) }}
Line 48: Line 47:
* Opt. 2H: 2-CH Zoom
* Opt. 2H: 2-CH Zoom
* Opt. 2M: Large Data Memory (add 2 MB)
* Opt. 2M: Large Data Memory (add 2 MB)
 
==Software==
* [[Media:Tektronix-2622,2630,2641,2642,Software_and_app._utilies_for_Tek_26xx_Fourier_Analyzer_2.26-2600.zip|DOS software and applications for 2622, 2630, 2641 and 2642]]
==Pictures==
==Pictures==
<gallery>
<gallery>
Line 54: Line 54:
</gallery>
</gallery>


[[Category: Spectrum Analyzers]]
[[Category:Spectrum analyzers]]

Latest revision as of 03:17, 11 September 2023

Tektronix 2622
20 kHz Fourier Analyzer
Tektronix 2622

Produced from 1990 to 1995

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 2622 is a Fourier analyzer that links dedicated signal acquisition and analysis with a personal computer’s mass storage and graphics. It allows measurement solutions for electrical, mechanical, and electromechanical applications in the DC to 20 kHz frequency range. Typical applications are Structural Analysis, Control Systems, Machine Vibration, Audio and Acoustic Tests, and General Purpose Signal and System Analysis.

Each of the channel inputs provide simultaneous sampling of all channels utilizing 12 bit ADC standard or 16 bit ADC optionally. Signal processing includes Fourier Transform (FFT) and Spectral Lines. The signal generator has a wide variety of functions, like sine, square, sawtooth, triangle, input, random, adjustable random, chirp, and arbitrary. With the optional TurboPac Application Library and Run-Time License advanced measurement calculations and graphs can be generated from the data collected.

The PC’s monitor displays the measurements results – but that’s where the Fourier Analyzer dependence on the PC stops. All of the data acquisition, data management, signal processing and other computationally intensive operations are reserved for the Fourier Analyzer’s high-performance measurement and analysis hardware. Built-in analog and digital anti-alias filters automatically track all of the bandwidth settings. A selection of frame sizes allows the user to choose the best trade-off between acquisition time and frequency resolution. When high frequency resolution around a specific signal is needed, the option "zoom" feature can be used. It allows one to focus up to 800 spectral line with a span as small as 10 Hz about the frequency of interest.

To learn more about FFT read Fast Fourier transform on at https://en.wikipedia.org/wiki/Fast_Fourier_transform.

Front panel inputs/outputs are: CH1 and CH2 each with a BNC connector (1 MΩ; 200 pF; ±30 V); and OUTPUT BNC connector (50Ω; ±10 V; signal general output capable of a variety of pre-defined, as well as user-defined, signals.)

Rear panel inputs/outputs are: SYSTEM INTERCONNECT DB9 connector (Male connector used for both External triggering, and External sampling inputs. All pins TTL-level except Signal ground: Pin 1 triggering signal input; pin 2 trigger sense output; pin 3 external clock input; pins 6 thru 8 signal ground; pin 9 is the external sampling input); and SERIAL PORT BNC connector (Female connector used linking to the host computer via a Tektronix supplied serial interface cable).


Specifications based on 1994 published documentation, unless otherwise specified.

Key Specifications

Frequency Ranges DC to 20 kHz
Max Real-time Bandwidth 5 kHz
Dynamic Range 75 dB
Standard Channels 2
Max Channels 2
Channel Match ±0.2 dB
Transient Capture Samples 500 K, extended to 1.5M with Opt. 2M (2 MB)
Spectral Lines 25 to 800
Input Impedance 1 MΩ; 200 pF
Max Input Level ±30 V
Included Accessories User Guide; Instrument Program Software; System Simulator Box; Power Cord; and Serial Interface Cable (please specify)
Weight Standard accessories: 5.5 kg (12 lbs)
Power 90 − 250 VAC, 48 to 66 Hz, >120 W
Operating Atmospherics Temperatures: 0 °C to +50 °C; Humidity: 95% for five days; Altitude: Up to 4.8 km (15,000 ft)

Options

  • Opt. 2H: 2-CH Zoom
  • Opt. 2M: Large Data Memory (add 2 MB)

Software

Pictures