P6136: Difference between revisions
Jump to navigation
Jump to search
m (Text replacement - "Category:1 MOhm Oscilloscope Probes" to "Category:1 MΩ Oscilloscope probes") |
No edit summary |
||
(4 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
{{Probe Sidebar | |||
|manufacturer=Tektronix | |||
|model=P6136 | |||
|summary=passive 350 MHz ×10 scope probe | |||
|image=TekP6136 10x.jpg | |||
|caption=P6136 | |||
|for=1 MΩ scope inputs | |||
|introduced=(?) | |||
|discontinued=(?) | |||
|manuals= | |||
* [[Media:070-6025-04.pdf|Tektronix P6136 Manual -04]] | |||
* [[Media:070-6025-01.pdf|Tektronix P6136 Manual -01]] | |||
}} | |||
The '''Tektronix P6136''' is a passive miniature 350 MHz ×10 scope probe for 1 MΩ // 12-18 pF scope inputs. | The '''Tektronix P6136''' is a passive miniature 350 MHz ×10 scope probe for 1 MΩ // 12-18 pF scope inputs. | ||
It has a ×10 readout pin, and shares accessories with many other Tektronix [[subminiature modular probes]]. | It has a ×10 readout pin, and shares accessories with many other Tektronix [[subminiature modular probes]]. The option 25 probe is identical in specifications but uses the [[Compact_modular_probes|compact series probe tip]]. | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
Line 11: | Line 23: | ||
{{Spec | Intended for | 2400 series }} | {{Spec | Intended for | 2400 series }} | ||
{{EndSpecs}} | {{EndSpecs}} | ||
==Links== | ==Links== | ||
* [http://www.barrytech.com/tektronix/probes/tekp6136.html P6136 @ barrytech.com] | * [http://www.barrytech.com/tektronix/probes/tekp6136.html P6136 @ barrytech.com] | ||
==Pictures== | |||
<gallery> | |||
Tek P6136.jpg | |||
P6136.jpg | |||
TekP6136 10x.jpg | P6136 Probe with clip lead | |||
</gallery> | |||
Latest revision as of 05:54, 15 October 2022
The Tektronix P6136 is a passive miniature 350 MHz ×10 scope probe for 1 MΩ // 12-18 pF scope inputs.
It has a ×10 readout pin, and shares accessories with many other Tektronix subminiature modular probes. The option 25 probe is identical in specifications but uses the compact series probe tip.
Key Specifications
Attenuation | 10× |
---|---|
Bandwidth | 350 MHz |
Compensation range | 12 to 25 pF |
Length | 1.3 m |
Intended for | 2400 series |
Links
Pictures
-
-
-
P6136 Probe with clip lead