TRCP0300: Difference between revisions
Jump to navigation
Jump to search
(Created page with "thumb|300px|right The '''Tektronix TRCP0300''' is a 300 A, AC-only oscilloscope current probe based on a Rogowski coil. The thin, flexible coil can e...") |
(Replaced external links with internal links.) |
||
(3 intermediate revisions by one other user not shown) | |||
Line 1: | Line 1: | ||
{{Probe Sidebar | |||
The '''Tektronix TRCP0300''' is a 300 A, AC-only oscilloscope current probe based on a Rogowski coil. | |manufacturer=Tektronix | ||
|model=TRCP0300 | |||
|summary=300 A AC current probe | |||
|image=TRCP0300 1.jpg | |||
|caption=TRCP0300 | |||
|for= | |||
|introduced=(?) | |||
|discontinued=(?) | |||
|manuals= | |||
* [[Media:60W-60294-3.pdf|TRCP0300 TRCP0600 TRCP3000 Current Probes Datasheet]] | |||
* [[Media:60W-60294-2.pdf|TRCP0300 TRCP0600 TRCP3000 Current Probes]] | |||
}} | |||
The '''Tektronix TRCP0300''' is a 300 A, AC-only oscilloscope current probe based on a [[wikipedia:Rogowski coil|Rogowski coil]]. | |||
The thin, flexible coil can easily be wrapped around test points such as the leg of a transistor. | The thin, flexible coil can easily be wrapped around test points such as the leg of a transistor. | ||
Line 8: | Line 20: | ||
{{Spec | Bandwidth | 9 Hz to 30 MHz }} | {{Spec | Bandwidth | 9 Hz to 30 MHz }} | ||
{{Spec | Current ranges | 250 mA to 300 A peak }} | {{Spec | Current ranges | 250 mA to 300 A peak }} | ||
{{Spec | Sensitivity | 20 mV/A }} | |||
{{Spec | Output | [[BNC connector]] to 1 MΩ scope input }} | |||
{{EndSpecs}} | {{EndSpecs}} | ||
''Please | ''Please expand'' | ||
[[Category:Oscilloscope current probes]] | [[Category:Oscilloscope current probes]] |
Latest revision as of 02:53, 23 December 2024
The Tektronix TRCP0300 is a 300 A, AC-only oscilloscope current probe based on a Rogowski coil.
The thin, flexible coil can easily be wrapped around test points such as the leg of a transistor.
Sister models TRCP0600 and TRCP3000 cover 600 A and 3000 A, respectively.
Key Specifications
Bandwidth | 9 Hz to 30 MHz |
---|---|
Current ranges | 250 mA to 300 A peak |
Sensitivity | 20 mV/A |
Output | BNC connector to 1 MΩ scope input |