The Tektronix P6023 is a ×10, 1000 V max. scope probe with 8 MΩ input resistance.
It has variable attenuation and compensation to permit equalizing a pair of these probes on a differential amplifier. The manual refers to Type W, 10A1, and 1A7 specifically.
Versions with BNC (010-0168-00) and UHF connectors (010-0097-00) exist.
Key Specifications
Bandwidth | 50 MHz |
---|---|
Risetime | < 7 ns |
Attenuation | adjustable 9.75-10.25 : 1 |
Input impedance | 7.8-8.2 MΩ // 12 pF |
Compensation range | 1 MΩ // 20-47 pF |
CMRR | Not specified |
Max. input | 1000 V (DC + peak AC) |