TransEra 641-RTC: Difference between revisions
No edit summary |
No edit summary |
||
(One intermediate revision by the same user not shown) | |||
Line 12: | Line 12: | ||
{{ROM Images}} | {{ROM Images}} | ||
* [[Media:TransEra-641-RTC-1978.bin|Original Firmware revision 1978]] | * [[Media:TransEra-641-RTC-1978.bin|Original Firmware revision 1978]] | ||
* [[Media:TransEra-641-RTC-1984.bin | * [[Media:TransEra-641-RTC-1984.bin|Original Firmware revision 1984]] | ||
* [[Media:TE-rtc-641_y2k.bin|1984 Firmware modified for Y2K compatibility]] | * [[Media:TE-rtc-641_y2k.bin|1984 Firmware modified for Y2K compatibility]] | ||
}} | }} | ||
Line 85: | Line 85: | ||
==Revisions== | ==Revisions== | ||
At least 3 revisions were released. The first version came without a battery, so all time information was lost after a | At least 3 revisions were released. | ||
The first version came without a battery, so all time information was lost after a power cycle. | |||
The second revision added a battery for counting the seconds within the year, but the year information was still unprotected. | |||
The manual of the [[TransEra 741-RTC]] explicitly talks about a 741-RTC and a 641-RTC with identical command set. The command set in the manual differs from the command set of the units shown on this page. | |||
Therefore, a third hardware revision of the 641 is presumed to exist. | |||
===Pictures revision 1=== | ===Pictures revision 1=== |
Latest revision as of 03:41, 2 October 2023
The TransEra 641 Real Time Clock ROM Pack (641-RTC) is a ROM pack for the 4051 microcomputer.
Command set
Command | Rev 1 | Rev 2 | Description |
---|---|---|---|
CALL "TIMSET", T | yes | yes | Sets the actual time. T must be a floating point number containing the count of seconds + fractions since the 01-01 of the current year. The resolution is 1/128 of a second. |
CALL "TIMSET",T$ | yes | yes | Sets the actual date & time. T$ must be a string in the format "MM-DD-YY HH:MM:SS". The time must be always given in 24h format. |
CALL "TIME",T | yes | yes | Returns the actual time. The result T is a floating point number and contains the count of seconds since 01-01 of the current year. The resolution is 1/128 of a second. |
CALL "TIME",T$ | yes | yes | Returns the actual date & time. rev1: |
CALL "CLOCK",T$ | no | yes | Same as "TIME",T$ and "TIME",T |
CALL "PAUSE",T | yes | yes | Pauses the Program for T seconds. The parameter T must be an integer value. The maximum delay is 65535 seconds (~18hours) After the pause the program execution starts at the next line. |
CALL "TIMER",T,L | yes | yes | Starts an asynchronous timer with the delay T and jumps to line L when the timer is done. The maximum delay is 65535 seconds (~18hours). The timer is not retriggered automatically. |
CALL "12HOUR" | no | yes | Sets the format of the returned time strings to 12-hour format. This is the default time format after a power-cycle. |
CALL "24HOUR" | no | yes | Sets the format of the returned time strings to 24-hour format. |
Revisions
At least 3 revisions were released.
The first version came without a battery, so all time information was lost after a power cycle.
The second revision added a battery for counting the seconds within the year, but the year information was still unprotected.
The manual of the TransEra 741-RTC explicitly talks about a 741-RTC and a 641-RTC with identical command set. The command set in the manual differs from the command set of the units shown on this page. Therefore, a third hardware revision of the 641 is presumed to exist.
Pictures revision 1
-
Label view
-
Top view of PCB
-
Bottom view of PCB
Pictures revision 2
-
Label view - Note: The first "TIMSET"-CALL is misspelled.
-
Front view
-
Top view of PCB
-
Bottom view of PCB
-
Schematic of revision 2