TDS3054: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(reduce marketing text)
No edit summary
 
(6 intermediate revisions by 2 users not shown)
Line 9: Line 9:
|discontinued=(?)
|discontinued=(?)
|manuals=
|manuals=
* [[Media:071-0274-01.pdf | 071-0274-01 TDS3000 Series User Manual]] (1.4 MB)
* [[Media:071-0274-01.pdf                                                             | 071-0274-01 TDS3000 Series User Manual   ]]
* [[Media:071-0382-01.pdf | 071-0382-01 TDS3000 Series Service Manual]] (1.5 MB)
* [[Media:071-0382-01.pdf                                                             | 071-0382-01 TDS3000 Series Service Manual ]]
* [[Media:TDS3000 Series Datasheet TDS3012 TDS3014 TDS3032 TDS3034 TDS3052 TDS3054.pdf | TDS3000 Series Datasheet]]
* [[Media:TDS3000 Series Datasheet TDS3012 TDS3014 TDS3032 TDS3034 TDS3052 TDS3054.pdf | TDS3000 Series Datasheet                 ]]
* [[Media:TDS3BATC-Rechargeable-Battery-Pack-Instructions-for-TDS3000-Series.pdf | TDS3BATC Battery Pack]]
* [[Media:071-0349-01.pdf                                                              | TDS3FFT User Manual                      ]]
* [[Media:071-0306-01.pdf                                                              | TDS3TRG User Manual                      ]]
* [[Media:TDS3BATC-Rechargeable-Battery-Pack-Instructions-for-TDS3000-Series.pdf       | TDS3BATC Battery Pack                     ]]
}}
}}
The '''Tektronix TDS3054''' is a four-channel, 500 MHz, 5 GS/s digital phosphor oscilloscope with 9-bit vertical resolution and a TFT color screen, with 3,600 wfms/s continuous waveform capture rate and real-time intensity grading.
The '''Tektronix TDS3054''' is a four-channel, 500 MHz, 5 GS/s digital phosphor oscilloscope with 9-bit vertical resolution and a TFT color screen, with 3,600 wfms/s continuous waveform capture rate and real-time intensity grading.
Line 20: Line 22:
Optional Communication Modules include the [[TDS3GM]] (GPIB/RS-232), [[TDS3VM]] (VGA/RS-232), [[TDS3EM]] (Ethernet/RS-232), [[TDS3GV]] (GPIB, RS-232/VGA), and the [[TDS3SDI]] 601 Serial/Digital Video Module.
Optional Communication Modules include the [[TDS3GM]] (GPIB/RS-232), [[TDS3VM]] (VGA/RS-232), [[TDS3EM]] (Ethernet/RS-232), [[TDS3GV]] (GPIB, RS-232/VGA), and the [[TDS3SDI]] 601 Serial/Digital Video Module.


Up to four Applications modules can be added into the small door in the upper right corner: [[TDS3AAM]] Advanced Analysis Module, [[TDS3LIM]] Limit Testing Module, [[TDS3TMT]] Telecommunications Mask Testing Module, and the [[TDS3VID]] Extended Video Analysis Module, [[TDS3TRG]] Advanced Trigger Module, and [[TDS3FFT]] Fast Fourier Transform Module.  The latter two functions were permanently enabled at [[TDS3000|TDS3000B]] firmware version 3.21, making those two application modules irrelevant.   
Up to four Applications modules can be added into the small compartment in the upper right corner: [[TDS3AAM]] Advanced Analysis Module, [[TDS3LIM]] Limit Testing Module, [[TDS3TMT]] Telecommunications Mask Testing Module, and the [[TDS3VID]] Extended Video Analysis Module, [[TDS3TRG]] Advanced Trigger Module, and [[TDS3FFT]] Fast Fourier Transform Module.  The latter two functions were permanently enabled at [[TDS3000|TDS3000B]] firmware version 3.21, making those two application modules irrelevant.   


There are many options for signal acquisition, measurement, and analysis.  The Getting Started section of the User Manual is a great place to become familiar with the many functions available.
There are many options for signal acquisition, measurement, and analysis.  The Getting Started section of the User Manual is a great place to become familiar with the many functions available.


{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | Bandwidth and channels | 500 MHz; Analog bandwidth limit 20 MHz or 150 MHz; 4 channels }}
{{Spec | Bandwidth             | 500 MHz (analog bandwidth limit 20 MHz or 150 MHz) }}
{{Spec | Vertical sensitivity  | 1 mV to 10 V/div (1 MΩ), 1 mV to 1 V/div (50 Ω) }}
{{Spec | Vertical sensitivity  | 1 mV to 10 V/div (1 MΩ), 1 mV to 1 V/div (50 Ω) }}
{{Spec | Timebase              | 1 ns to 10 s/div }}
{{Spec | Timebase              | 1 ns to 10 s/div }}
Line 35: Line 37:


==Links==
==Links==
* [https://github.com/andrewpono/TDS3000-Series-Gotek-FlashFloppy Instructions on replacing the floppy drive with a USB emulator]
* [https://github.com/andrewpono/TDS3000-Series-Gotek-FlashFloppy Instructions on replacing the floppy drive with a USB emulator]
* [https://www.youtube.com/watch?v=leC-zSMbtfg  EEVblog teardown and repair]
{{Documents|Link=TDS3054}}
{{PatentLinks|TDS3054}}


==Pictures==
==Pictures==

Latest revision as of 05:34, 23 September 2024

Tektronix TDS3054
Digital Storage 500 MHz 4-channel scope
Tektronix TDS3054

Produced from 1998 to (?)

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix TDS3054 is a four-channel, 500 MHz, 5 GS/s digital phosphor oscilloscope with 9-bit vertical resolution and a TFT color screen, with 3,600 wfms/s continuous waveform capture rate and real-time intensity grading.

The original and -B versions had a Floppy Disk drive and Centronics printer port. The C version replaced the Floppy with a USB drive, and dropped the the parallel port.

Optional Communication Modules include the TDS3GM (GPIB/RS-232), TDS3VM (VGA/RS-232), TDS3EM (Ethernet/RS-232), TDS3GV (GPIB, RS-232/VGA), and the TDS3SDI 601 Serial/Digital Video Module.

Up to four Applications modules can be added into the small compartment in the upper right corner: TDS3AAM Advanced Analysis Module, TDS3LIM Limit Testing Module, TDS3TMT Telecommunications Mask Testing Module, and the TDS3VID Extended Video Analysis Module, TDS3TRG Advanced Trigger Module, and TDS3FFT Fast Fourier Transform Module. The latter two functions were permanently enabled at TDS3000B firmware version 3.21, making those two application modules irrelevant.

There are many options for signal acquisition, measurement, and analysis. The Getting Started section of the User Manual is a great place to become familiar with the many functions available.

Key Specifications

Bandwidth 500 MHz (analog bandwidth limit 20 MHz or 150 MHz)
Vertical sensitivity 1 mV to 10 V/div (1 MΩ), 1 mV to 1 V/div (50 Ω)
Timebase 1 ns to 10 s/div
Sample rate 5 GS/s on each channel
Record length 10 K points
Waveform measurements 25 Automatic, waveform add, subtract, divide, and multiply math functions, Fast Fourier Transform (FFT), Advanced Math (Integrate, Differentiate, Define extensive algebraic expressions, math functions, scalars, user adjustable variables)
Battery operation up to 3 hours with optional TDS3BATC rechargeable lithium-ion battery pack

Links

Documents Referencing TDS3054

(no results)

Patents that may apply to TDS3054

Page Title Inventors Filing date Grant date Links
Patent US 4271488A High-speed acquisition system employing an analog memory matrix Charles L. Saxe 1979-04-13 1981-06-02
Patent US 4251754A Digital oscilloscope with reduced jitter due to sample uncertainty Luis Navarro Thomas P. Dagostino 1979-09-04 1981-02-17
Patent US 4251815A Signal-envelope display system for a digital oscilloscope Thomas P. Dagostino 1979-09-18 1981-02-17
Patent US 4476432A Waveform measurement system David H. Olson 1982-02-10 1984-10-09
Patent US 4561049A Control system employing a rotary knob Sam M. Deleganes Steven C. Den Beste 1983-03-23 1985-12-24
Patent US 4647862A Trigger holdoff system for a digital oscilloscope Bruce W. Blair 1984-09-04 1987-03-03
Patent US 4965800A Digital signal fault detector William A. Farnbach 1988-10-11 1990-10-23
Patent US 5032801A High performance attenuator configuration Jim Woo Marv LaVoie 1990-07-31 1991-07-16
Patent US 5387896A Rasterscan display with adaptive decay Kuriappan P. Alappat Edward E. Averill 1990-08-06 1995-02-07
Patent US 5144525A Analog acquisition system including a high speed timing generator Charles L. Saxe Steven K. Sullivan Grigory Kogan 1990-09-27 1992-09-01
Patent US 5550963A Graded display of digitally compressed waveforms Roy I. Siegel John A. Hengeveld 1994-12-08 1996-08-27

Pictures