180: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(3 intermediate revisions by one other user not shown)
Line 13: Line 13:
* [[Media:Tek 180 manual.pdf|Tektronix 180 Manual]]
* [[Media:Tek 180 manual.pdf|Tektronix 180 Manual]]
* [[Media:070-358.pdf|Tektronix 180A Manual]]
* [[Media:070-358.pdf|Tektronix 180A Manual]]
* [https://w140.com/tek_fcp/tek_type_180_field_recal_proc.pdf Tektronix 180 Field Recalibration Procedure]
* [[Media:Tek type 180 field recal proc.pdf|Tektronix 180 Field Recalibration Procedure]]
* [https://w140.com/tek_fcp/tek_type_180a_factory_cal_proc.pdf Tektronix 180A Factory Calibration Procedure]
* [[Media:Tek type 180a factory cal proc.pdf|Tektronix 180A Factory Calibration Procedure]]
* [[Media:Tek 180 180a irb.pdf|Tektronix 180 and 180A Instrument Reference Book]]
* [[Media:Tek 180 180a irb.pdf|Tektronix 180 and 180A Instrument Reference Book]]
* [[Media:Tek 180a fcp.pdf|Tektronix 180A Factory Calibration Procedure (1963-06-04)]]
* [[Media:Tek 180a fcp.pdf|Tektronix 180A Factory Calibration Procedure (1963-06-04)]]
Line 52: Line 52:


==See Also==
==See Also==
* [[Media:Gr oscillator calibration with 180a.pdf|GR Oscillator Calibration with 180A (PDF, needs OCR)]]
* [[Media:Gr oscillator calibration with 180a.pdf|GR Oscillator Calibration with 180A (OCR)]]
* [[Media:Tek discussion of hickok clone of 180a.pdf]]
* [[Media:Tek discussion of hickok clone of 180a.pdf|Tek Discussion of Hickok Clone of Tek 180A]]


==Pictures==
==Pictures==
Line 107: Line 107:
Tek 180a late sn power supply.png|late sn power supply
Tek 180a late sn power supply.png|late sn power supply
</gallery>
</gallery>
[[Category:Time mark generators]]

Latest revision as of 08:33, 25 October 2024

Tektronix 180
Time-mark generator
Tektronix 180A Time-mark generator

Produced from 1958 to (?)

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix 180A was introduced in 1958 and is an all-tube time mark generator with an oven-controlled crystal oscillator (OCXO).

Time mark generators put out pulses at user-selectable intervals. They are primarily used for calibrating the time-base of oscilloscopes. Switches on the front panel select which of the divided-down pulse signals will be added together to form the output waveform. The Tektronix 180 has toggle switches. The 180A has pushbutton switches.

The signal path of the 180A starts with an OCXO producing 1 MHz, which is then divided down using synchronized monostable multivibrators. This scheme does not require precision in the time constant of the monostable multivibrators. The only precision component in the 180A is the OCXO (part number 158-007).

In addition to the time mark generator functionality, the 180A also produces sine waveforms at 5 MHz, 10 MHz, and 50 MHz. These frequencies are produced by feeding the 1 MHz OCXO output to a series of three frequency multipliers. First the 1 MHz is quintupled to get the 5 MHz signal. Then the 5 MHz signal is doubled to the 10 MHz signal. Then the 10 MHz signal is quintupled, yielding the 50 MHz signal. Each of the three frequency multipliers is composed of a 6DK6 pentode driving an LC resonator tuned to 5 MHz, 10 MHz, and 50 MHz.

The 180A manual suggests an interesting procedure for calibrating the OCXO, by attaching a small antenna to deliberately interfere with the national time standard broadcast, and observing the interference with a communication receiver.

The method is to zero-beat the WWV standard frequency broadcast with the internal crystal oscillator to align the OCXO frequency. First tune ham receiver to WWV broadcast - say 10 MHz - and watch the audio subtone using an oscilloscope connected to the audio out of the receiver. Then wait for specific minutes of the hour where there is no audio subtone in WWV. Then select 1 μs output on 180A, which will have 10 MHz as the harmonic. Connect a wire from the output of the 180A as an antenna and couple it to the antenna input of the receiver. This way, the 10 MHz WWV and 10 MHz harmonic from the 180A will beat in the receiver input, and the difference will be visible as a wave in the oscilloscope. Then adjust C105 to align the crystal frequency so close to the reference WWV 10 MHz that the frequency difference becomes zero or the waveform on the scope becomes flat.

You could also use the S-Meter in the receiver instead of the oscilloscope to perform the same.

The 180A, serial number 5599 and up, uses the 120-119 power transformer.