title=Tektronix 11A71 |
|manufacturer=Tektronix
summary=Single channel 1 GHz amplifier |
|series=11000-series scopes
image=11a71-ext.jpg |
|type=11A71  
caption=Tek 11A71 |
|summary=Single channel 1 GHz amplifier  
series=[[11000-series scopes]] |
|image=11a71-ext.jpg  
introduced=1987 |
|caption=Tek 11A71  
discontinued=(?) |
|introduced=1987  
manuals=
|discontinued=(?)  
|designers=
|manuals=
* [http://w140.com/tek_11a71_service.pdf Tektronix 11A71 Service Manual (PDF)]
* [http://w140.com/tek_11a71_service.pdf Tektronix 11A71 Service Manual (PDF)]
* [[Media:Tek 11A71 schematics.pdf|Tektronix 11A71 Schematics]]
* [[Media:Tek 11A71 schematics.pdf|Tektronix 11A71 Schematics]]
Line 14: Line 16:
The '''Tektronix 11A71''' a single-channel 1 GHz amplifier for 11000-series scopes.   
The '''Tektronix 11A71''' a single-channel 1 GHz amplifier for 11000-series scopes.   


The 11A71 is derived from the [[7A29]].
The 11A71 is derived from the [[7A29]]. However, the 7A29 has a VARIABLE gain control while the 11A71 does not, it has only the 1-2-5 gain sequence.
However, the 7A29 has a VARIABLE gain control while the 11A71 does not, it has only the 1-2-5 gain sequence.


The 7A29 and 11A71 have virtually the same analog circuitry including a Gilbert multiplier at the front end,
The 7A29 and 11A71 have virtually the same analog circuitry including a Gilbert multiplier at the front end, but in the 11A71 it is only used for automatic calibration, not for fine gain control.
but in the 11A71 it is only used for automatic calibration, not for fine gain control.
This is feature regression, but it avoids an issue that the 7A29 has, namely that its bandwidth changes substantially with the setting of the front panel VARIABLE VOLTS/DIV control.
This is feature regression, but it avoids an issue that the 7A29 has, namely that its bandwidth changes substantially with the setting of the front panel VARIABLE VOLTS/DIV control.


After calibration, there is a small imbalance in the 10 mV/div setting, about 0.05 div.
After calibration, there is a small imbalance in the 10 mV/div setting, about 0.05 div. This is a design flaw.
This is a design flaw.


{{BeginSpecs}}
{{BeginSpecs}}
Line 31: Line 30:
{{Spec | Input impedance | 50 Ω via a [[Tekprobe BNC connector]] on the front on the plug-in}}
{{Spec | Input impedance | 50 Ω via a [[Tekprobe BNC connector]] on the front on the plug-in}}
{{Spec | Features |
{{Spec | Features |
*Input 5 V<sub>RMS</sub> overload protected with manual reset
* Input 5 V<sub>RMS</sub> overload protected with manual reset
}}
}}
{{EndSpecs}}
{{EndSpecs}}