434: Difference between revisions

4,033 bytes removed ,  27 February 2022
no edit summary
(WL)
No edit summary
Line 8: Line 8:
discontinued=1984 |
discontinued=1984 |
manuals=
manuals=
* [http://w140.com/tektronix_434_service.pdf Tektronix 434 Manual sn 500,000 and up (complete, PDF)]
* [[Media:070-1915-00.pdf|Tektronix 434 Instruction Manual SN 500,000+]] (complete, OCR)
* [http://w140.com/434_below_B500000.pdf Tektronix 434 Manual sn below 500,000 (complete, PDF)]
* [[Media:070-1131-00.pdf|Tektronix 434 Instruction Manual, SN <500,000]] (complete, OCR)
* [[Media:Tek 432 and 434 fcp april 1972.pdf|Tektronix 432 and 434 Factory Calibration Procedure, April 1972]] (PDF)
<!-- old non-wiki upload locations
* [http://w140.com/tektronix_434_service.pdf Tektronix 434 Manual sn 500,000 and up] (complete)
* [http://w140.com/434_below_B500000.pdf Tektronix 434 Manual sn below 500,000] (complete)]
* [http://w140.com/tek_434.pdf Tektronix 434 Manual (incomplete, PDF)]
* [http://w140.com/tek_434.pdf Tektronix 434 Manual (incomplete, PDF)]
 
-->
* [[Media:070-1915-00.pdf|Tektronix 434 Manual sn 500,000and up (complete, PDF, OCR, bad-OCR)]]
* [[Media:070-1131-00.pdf|Tektronix Maunal sn below 500,000 (complete, PDF, OCR)]]
* [[Media:Tek 432 and 434 fcp april 1972.pdf|Tektronix 432 and 434 Factory Calibration Procedure, April 1972 (PDF, needs OCR)]]
}}
}}
The '''Tektronix 434''' is an analog [[CRT storage scope]] with two independent storage areas on the screen.  
The '''Tektronix 434''' is an analog [[CRT storage scope]] with two independent storage areas on the screen.  
Line 41: Line 42:


==Repair Issues==
==Repair Issues==
In general, the 434 is a nice-looking, easy-to-use oscilloscope.
See → [[434/Repairs|Repairs page]].
However, the 434 was probably one of the worst ''mechanical'' scope designs to come out of Beaverton engineering.
This was the model that caused bench technicians to think that the factory should send all new mechanical engineers
out into the field to work at a Service Center for a year to get an idea of good and bad mechanical designs. 
 
First of all, the 434 design departed from the proven 4-40 steel PCB mounting screws.
Instead, it uses 3-48 brass screws in a design that requires a screw-holding driver to get the fasteners in place.
Brass screws are non-magnetic and getting them started
in some of the more obscure places on the vertical preamp board is extremely difficult.
Since these scopes are of an age that one can make modifications without incurring the wrath of Tektronix technicians,
it is suggested that these brass screws be replaced with steel 3-48 screws,
preferably ones with captive washers like the original brass screws.
Most dedicated Tektronix fans and ex-technicians do not like changing any circuit design from the original,
but some mechanical changes such as this are for everyone's benefit
and don't affect operation of the oscilloscope in the least.
In fact, if the circuit boards are removed, the original 3-48 threaded holes
in the castings can be drilled out and retapped for 4-40 screws.
 
If the V/DIV knob skirt lamps go out, the vertical preamp board must be removed to replace them.
This is a process involving the removal of a lot of the aforementioned brass 3-48 screws,
the removal of some connectors, the unsoldering of a lot of wires
and the removal of knobs and shafts all over that area of the front panel.
Remember, it is always better to leave those red VAR V/DIV knobs on their shafts and
instead remove knob and shaft as a unit by loosening it from the coupler on the potentiometer itself.
Since these oscilloscopes are considered obsolete, the suggestion is to replace
ALL of the vertical knob skirt lamps with light emitting diodes, choosing either white or yellow LEDs.
These lamps already have small-value current limiting resistors on the circuit board that are in series,
so replacing these resistors with the appropriate value to limit LED current is an easy process.
Be careful that you select an appropriate power rating for the resistors.
It is suggested that current be limited so that the panel lighting is sufficient for bright room lighting,
but not so bright as to make it difficult to read the numbers on the knob skirts.
 
The 434 uses only two plug-in attenuators (both ×10) in each channel,
and most V/DIV switching involves gain switching of the preamp.
The 434 often cannot meet vertical gain specifications and
some very low-value 5% tolerance resistors must be replaced to correct this.
These resistors are not located in an easy-to-access area of the board
and once the defective resistors are identified,
the board will need to be removed to allow replacement of the resistors without board damage.
 
Another common problem involves the mounting hardware for the back casting.
Nearly every 434 that was received in Tektronix Service Centers had to have these mounting screws tightened.
There is one located under the cover for the line cord and fuse. If that screw comes completely out,
it is held captive inside that small space, and causes a lot of damage to the open mains connections on the fuse holder.
This is a job for a #2 Pozidriv screwdriver and a LOT of muscle torque.
Don't use a Phillips driver for this because it will "cam out" of the screw head with the torque that you must apply,
causing screw head damage.  Regardless of how much torque you apply,
you won't strip the extruded aluminum rails or break the large 10-32 screws.
Tighten all of these casting-mounting screws by hand as tight as you possibly can.
Of course, do not use high-torque pneumatic or electric tools for this job.
Especially don't use the electric impact drivers that are so popular now in the construction industry.
The hardware DOES have its mechanical limitations.