7D14: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(+cats, template)
(basic specs)
Line 12: Line 12:


The '''Tektronix 7D14''' is a 525 MHz frequency counter plug-in for [[7000-series scopes|7000 series mainframes]].
The '''Tektronix 7D14''' is a 525 MHz frequency counter plug-in for [[7000-series scopes|7000 series mainframes]].
It uses the mainframe's readout system to display an eight-digit count on the CRT.
Modes include frequency, frequency ratio and events count using manual or external gate.
When installed in a horizontal compartment, it can count the trigger pickoff from a vertical amplifier unit.  This allows simultaneous viewing and counting of a signal in four-bay mainframes.
In a vertical compartment, the trigger signal (i.e. the "shaped" input) can be displayed as the module's Y output.


==Specifications==
==Specifications==
[[Category:Specifications needed]] ''please add''
 
{{BeginSpecs}}
{{Spec | Frequency | 525 MHz (5 MHz bandwidth limiting switch available) }}
{{Spec | Sensitivity | 100 mV to 10 V }}
{{Spec | Input Impedance | 50 Ω or 1 MΩ // 20 pF on external input, 1.5 Div internal when set to "Trig Source"}}
{{Spec | Gate time | 1 ms to 10 s }}
{{Spec | Display time | 0.1 s to 5 s or infinite }}
{{Spec | Features |
* Gate monitor output / Ext Gate input ([[BSM]])
* 1 MHz reference monitor output / Ext Ref input (BSM)
}}
{{EndSpecs}}


==Links==
==Links==

Revision as of 10:04, 24 June 2014

{{{manufacturer}}} Special Function
525 MHz frequency counter
7D14 front view (manual)

Compatible with [[7000-series scopes]]

Produced from {{{introduced}}} to {{{discontinued}}}

Manuals
(All manuals in PDF format unless noted otherwise)
[[Category:Introduced in {{{introduced}}}]]
Manuals – Specifications – Links – Pictures


The Tektronix 7D14 is a 525 MHz frequency counter plug-in for 7000 series mainframes.

It uses the mainframe's readout system to display an eight-digit count on the CRT. Modes include frequency, frequency ratio and events count using manual or external gate.

When installed in a horizontal compartment, it can count the trigger pickoff from a vertical amplifier unit. This allows simultaneous viewing and counting of a signal in four-bay mainframes.

In a vertical compartment, the trigger signal (i.e. the "shaped" input) can be displayed as the module's Y output.

Specifications

Key Specifications

Frequency 525 MHz (5 MHz bandwidth limiting switch available)
Sensitivity 100 mV to 10 V
Input Impedance 50 Ω or 1 MΩ // 20 pF on external input, 1.5 Div internal when set to "Trig Source"
Gate time 1 ms to 10 s
Display time 0.1 s to 5 s or infinite
Features
  • Gate monitor output / Ext Gate input (BSM)
  • 1 MHz reference monitor output / Ext Ref input (BSM)

Links

Pictures

please add