The Tektronix Type 106 is a | The '''Tektronix Type 106''' is a square-wave generator [[introduced in 1966]]. It has four outputs: | ||
<ul> | <ul> | ||
<li><b>Fast Rise +Output:</b> 500mV into | <li><b>Fast Rise +Output:</b> 500mV into 50 Ω load, positive-going pulse, 1 ns rise time, 50 Ω output impedance, GR connector | ||
<li><b>Fast Rise -Output:</b> 500mV into | <li><b>Fast Rise -Output:</b> 500mV into 50 Ω load, negative-going pulse, 1 ns rise time, 50 Ω output impedance, GR connector | ||
<li><b>High Amplitude Output:</b> | <li><b>High Amplitude Output:</b> 12 V into 50 Ω load, 12 ns rise time, 600 Ω output impedance, GR connector | ||
<li><b>Trigger Output:</b> | <li><b>Trigger Output:</b> 100 mV into 50 Ω load, 50 ns rise time, 150 Ω output impedance, BNC connector | ||
</ul> | </ul> | ||
The | The 1 ns rise-time outputs are generated using diodes to clip a high | ||
clip a high amplitude signal. In units with serial numbers less than 1190, GaAs diodes were used | amplitude signal. In units with serial numbers less than 1190, GaAs diodes | ||
for clipping. After serial number 1190, silicon diodes were used. | were used for clipping. After serial number 1190, silicon diodes were used. | ||
The high amplitude output stage of the 106 is made of four [[7189|7189A]] tubes in parallel. With moderate effort, the socket wiring can be made compatible with the [[7189]] aka [[6BQ5]]. | The high amplitude output stage of the 106 is made of four [[7189|7189A]] tubes in parallel. With moderate effort, the socket wiring can be made compatible with the [[7189]] aka [[6BQ5]]. | ||
==Manuals== | |||
* [http://w140.com/tek_106.pdf Tektronix 106 Manual (PDF)] | * [http://w140.com/tek_106.pdf Tektronix 106 Manual (PDF)] | ||
* [http://w140.com/106.djvu Tektronix 106 Manual (DjVu)] | * [http://w140.com/106.djvu Tektronix 106 Manual (DjVu)] | ||
==Pictures== | |||
<gallery> | <gallery> | ||
Image:Tek 106 front.jpg|Front | Image:Tek 106 front.jpg|Front | ||
Line 34: | Line 36: | ||
[[Category:Pulse generators]] | [[Category:Pulse generators]] | ||
[[Category:Introduced in 1966]] |
Revision as of 00:46, 19 August 2014
The Tektronix Type 106 is a square-wave generator introduced in 1966. It has four outputs:
- Fast Rise +Output: 500mV into 50 Ω load, positive-going pulse, 1 ns rise time, 50 Ω output impedance, GR connector
- Fast Rise -Output: 500mV into 50 Ω load, negative-going pulse, 1 ns rise time, 50 Ω output impedance, GR connector
- High Amplitude Output: 12 V into 50 Ω load, 12 ns rise time, 600 Ω output impedance, GR connector
- Trigger Output: 100 mV into 50 Ω load, 50 ns rise time, 150 Ω output impedance, BNC connector
The 1 ns rise-time outputs are generated using diodes to clip a high amplitude signal. In units with serial numbers less than 1190, GaAs diodes were used for clipping. After serial number 1190, silicon diodes were used.
The high amplitude output stage of the 106 is made of four 7189A tubes in parallel. With moderate effort, the socket wiring can be made compatible with the 7189 aka 6BQ5.