P6000: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 1: Line 1:
The Tektronix P6000 is a 30MHz 10x passive voltage probe designed for use with  
[[File:Tek p6000.jpg|thumb|300px|right]]
oscilloscopes that have a 1 megohm input impedance.
The '''Tektronix P6000''' is a 30 MHz,  ×10 passive voltage probe designed for use with  
Maximum voltage is 1200.  Input capacitance is from 11.5 to 14.5 pF.   
oscilloscopes that have a 1 MΩ // 20 to 50 pF input impedance and a [[UHF connector]].
The connection with the scope is with a [[UHF connector]].
 
The compensation range is 20pF to 50pF.
Probe input impedance is 10 MΩ // 11.5 to 14.5 pF.   
Maximum voltage is 1200 V.
The connection with the scope is with  


The P6000 was made with four different cable lengths:
The P6000 was made with four different cable lengths:
Line 11: Line 13:
* 12 feet, part number 010-0041-00
* 12 feet, part number 010-0041-00


==Manuals==


* [http://w140.com/tek_p6000_old.pdf Tektronix P6000 Manual (older, PDF)]
* [http://w140.com/tek_p6000_old.pdf Tektronix P6000 Manual (older, PDF)]
* [http://w140.com/tek_p6000_new.pdf Tektronix P6000 Manual (newer, PDF)]
* [http://w140.com/tek_p6000_new.pdf Tektronix P6000 Manual (newer, PDF)]


<gallery>
 
image:Tek p6000.jpg
</gallery>
[[Category:1 MOhm Oscilloscope Probes]]
[[Category:1 MOhm Oscilloscope Probes]]

Revision as of 00:18, 13 September 2016

The Tektronix P6000 is a 30 MHz,  ×10 passive voltage probe designed for use with oscilloscopes that have a 1 MΩ // 20 to 50 pF input impedance and a UHF connector.

Probe input impedance is 10 MΩ // 11.5 to 14.5 pF. Maximum voltage is 1200 V. The connection with the scope is with

The P6000 was made with four different cable lengths:

  • 3.5 feet, part number 010-0020-00
  • 6 feet, part number 010-0030-00
  • 9 feet, part number 010-0035-00
  • 12 feet, part number 010-0041-00

Manuals