454: Difference between revisions
No edit summary |
No edit summary |
||
Line 3: | Line 3: | ||
summary=150 MHz portable dual-trace scope | | summary=150 MHz portable dual-trace scope | | ||
image=Tek_454a_trace.jpg | | image=Tek_454a_trace.jpg | | ||
caption=Tektronix | caption=Tektronix 454A front | | ||
introduced=1967 | | introduced=1967 | | ||
discontinued=1974 | | discontinued=1974 | | ||
Line 48: | Line 48: | ||
File:454 trig.gif | File:454 trig.gif | ||
File:454 vert out.gif | File:454 vert out.gif | ||
Tek 454 square sin.jpg | |||
Tek 454 intensified.jpg | |||
Tek 454 with lid on.jpg | |||
Tek 454 rear.jpg | |||
Tek 454 right side.jpg | |||
</gallery> | </gallery> | ||
[[Category:400 series scopes]] | [[Category:400 series scopes]] | ||
[[Category:Specifications needed]] | [[Category:Specifications needed]] |
Revision as of 17:15, 2 November 2017
The Tektronix 454 is a 150 MHz portable dual-trace scope introduced in March 1967.
It can be seen as an improved 453. The successor 454A was introduced in 1971.
The 454 is the fastest general-purpose Tektronix scope that does not use proprietary hybrid or integrated circuits. It uses a CRT with distributed vertical deflection plates.
Specifications
With the input sensitivity set to 10 mV/div and above, the 454A has a vertical bandwidth of 150 MHz. At 5 mV/div it is 100 MHz, and at 2 mV/div it is 50 MHz.
It is possible to cascade the channel-1 and channel-2 input amplifiers to obtain a sensitivity of 400 μV/div. In that configuration, the vertical bandwidth is 33 MHz.
The 454 weighs 29 pounds and consumes about 130 watts. please add
Internals
The 454 has a 140 ns delay line in the signal path after the input channel switching and before the main vertical amplifier. There is a phase equalizer after the delay line to mitigate the harm done to pulse fidelity by the delay line.
Links
Pictures
-
454A Front
-
454A Bottom
-
454A Vertical amp
-
454A Top
-
-
-
-
-
-
-