ground and the potentiometer divider arm connected to the attenuator output. | ground and the potentiometer divider arm connected to the attenuator output. | ||
The attenuator is not matched to any particular impedance system. It will attenuate a 1 ns rise-time pulse in a 50 Ω system with negligible distortion. | The attenuator is not matched to any particular impedance system, | ||
although input and output are 50 Ω [[GR-874 connector]]s. | |||
It will attenuate a 1 ns rise-time pulse in a 50 Ω system with negligible distortion. | |||
<gallery> | <gallery> | ||
Line 20: | Line 20: | ||
Tek 067-0511-00 10.jpg | Tek 067-0511-00 10.jpg | ||
</gallery> | </gallery> | ||
[[Category:Calibration fixtures]] |
Revision as of 12:07, 17 January 2019
The Tektronix 067-0511-00 is a variable attenuator which has the end terminals of a 100 Ω potentiometer connected from input to ground and the potentiometer divider arm connected to the attenuator output.
The attenuator is not matched to any particular impedance system, although input and output are 50 Ω GR-874 connectors. It will attenuate a 1 ns rise-time pulse in a 50 Ω system with negligible distortion.