{{Spec | Maximum Safe Input Voltage | 400 V (dc + peak AC) or 800 V<sub>p-p</sub> AC to 1 kHz or less }}
{{Spec | Maximum Safe Input Voltage | 400 V (dc + peak AC) or 800 V<sub>p-p</sub> AC to 1 kHz or less }}
{{Spec | CMRR | At least 10:1 at 10 MHz }}
{{Spec | CMRR | At least 10:1 at 10 MHz }}
{{EndSpecs}}
{{SpecGroup | Horizontal}}
{{Spec | Timebase | 50 ns/Div to 500 ms/Div, 1-2-5,  ×10 magnifier, i.e. down to 5 ns/Div}}


=== Trigger ===
{{SpecGroup | Trigger}}
* Auto / Norm
{{Spec | Sensitivity | 0.4 Div internal / 50 mV external up to 2 MHz; 1.5 Div internal / 250 mV external up to 60 MHz}}
** <= 2MHz : 0.4 division internal or 50mV external  
{{Spec | AC coupled trigger | ≤10 Hz (-3 dB) }}
** <= 60 MHz : 1.5 divisions internal or 250mV external
{{Spec | External trigger input | max. 400 V (DC+peak AC) or 800 V<sub>p-p</sub> AC to 1kHz or less; impedance 1 MΩ ±2% // 30 ±3 pF}}
* TV Field
{{Spec | Trigger modes | Auto, Norm, TV Field }}
* External input :
{{SpecGroup | Miscellaneous}}
** Maximum Input Voltage : 400V (dc + peak AC) or 800V p-p AC to 1kHz or less
{{Spec | Features |
** Input Characteristics : 1M +- 2% ; 30pF +- 3pF
** AC Coupled : 10Hz or less at lower -3dB point
 
=== Horizontal ===
* 0.5s to 50ns per division in a 1-2-5 sequence. X10 Magnifier extends to 5ns per div.
 
=== Misc ===
* X-Y operation
* X-Y operation
* Probe adjust (0.5V at 1kHz)
* Probe adjust (0.5V at 1kHz)
* Z axis input (intensity); DC to 5MHz
}}
* CRT display area : 80 x 100mm
{{Spec | Z axis | input (intensity); DC to 5 MHz}}
* Weight : 6.1kg; 7.6kg with front panel cover + accessories and pouch
{{Spec | CRT | display area : 80 × 100 mm² }}
* Dimensions with feet and handle: 137 x 361 x 511 mm
{{Spec | Weight | 6.1 kg; 7.6 kg with front panel cover, accessories and pouch}}
{{Spec | Dimensions | With feet and handle: 137 x 361 x 511 mm³ }}
{{EndSpecs }}


==Pictures ==
<gallery>
<gallery>
Tek 2215a front.jpg
Tek 2215a front.jpg

Revision as of 06:10, 17 December 2016

{{{manufacturer}}} 
60 MHz dual trace scope
Tektronix 2215

Produced from 1982 to (?)

Manuals

Modifications

(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures


The Tektronix 2215 is a portable dual-trace 60 MHz scope from the 2000-series of low-cost analog scopes.

There is also a 2215A (same specifications as 2215 with improved CRT intensity and bandwidth limit ?)

Key Specifications

     — Vertical
Deflection 2 mV to 10 V per division, 1-2-5
Rise time < 5.8 ns (calculated)
Bandwidth DC to >60 MHz, 20 mV/Div to 10 V/Div, 0 °C to +40 °C; >50 MHz in 2 mV/Div to 10 mV/Div ranges or from +40 °C to +50 °C
Input impedance 1 MΩ ±2% // 30 ±3 pF
Maximum Safe Input Voltage 400 V (dc + peak AC) or 800 Vp-p AC to 1 kHz or less
CMRR At least 10:1 at 10 MHz
     — Horizontal
Timebase 50 ns/Div to 500 ms/Div, 1-2-5,  ×10 magnifier, i.e. down to 5 ns/Div
     — Trigger
Sensitivity 0.4 Div internal / 50 mV external up to 2 MHz; 1.5 Div internal / 250 mV external up to 60 MHz
AC coupled trigger ≤10 Hz (-3 dB)
External trigger input max. 400 V (DC+peak AC) or 800 Vp-p AC to 1kHz or less; impedance 1 MΩ ±2% // 30 ±3 pF
Trigger modes Auto, Norm, TV Field
     — Miscellaneous
Features
  • X-Y operation
  • Probe adjust (0.5V at 1kHz)
Z axis input (intensity); DC to 5 MHz
CRT display area : 80 × 100 mm²
Weight 6.1 kg; 7.6 kg with front panel cover, accessories and pouch
Dimensions With feet and handle: 137 x 361 x 511 mm³

Pictures