* [http://w140.com/tek_3s7_3t7_with_index.pdf Tektronix 3S7/3T7 Manual (PDF)] | * [http://w140.com/tek_3s7_3t7_with_index.pdf Tektronix 3S7/3T7 Manual (PDF)] | ||
}} | }} | ||
The Tektronix Type 3T7 is a [[sampling_oscilloscope|sampling]] timebase and pulser plug-in for [[560-series scopes]]. The 3T7 was [[introduced in 1971]]. Used with a [[3S7]], a TDR system is formed. | The Tektronix Type 3T7 is a [[sampling_oscilloscope|sampling]] timebase and pulser plug-in for [[560-series scopes]]. | ||
The 3T7 was [[introduced in 1971]]. | |||
Used with a [[3S7]], a TDR system is formed. | |||
The pulse is produced by a 21 mA, 1.5 pF [[tunnel diodes|tunnel diode]], CR587, made by GE with Tektronix part number [[152-0489-00]]. | The pulse is produced by a 21 mA, 1.5 pF [[tunnel diodes|tunnel diode]], CR587, made by GE with Tektronix part number [[152-0489-00]]. | ||
Line 24: | Line 26: | ||
<gallery> | <gallery> | ||
3t7_front.JPG|Front | |||
3t7_left.JPG|Left | |||
3t7_right.JPG|Right | |||
3t7_top.JPG|Top | |||
3t7_bottom.JPG|Bottom | |||
</gallery> | </gallery> | ||
Revision as of 17:10, 3 February 2018
Template:Plugin Sidebar 2 The Tektronix Type 3T7 is a sampling timebase and pulser plug-in for 560-series scopes. The 3T7 was introduced in 1971. Used with a 3S7, a TDR system is formed.
The pulse is produced by a 21 mA, 1.5 pF tunnel diode, CR587, made by GE with Tektronix part number 152-0489-00.
The interface between the GR-874 connector and the printed circuit board is described in US Patent 3,426,311.
The 3T7 uses a CA3051 dual amplifier chip.
Specifications
please add
Pictures
-
Front
-
Left
-
Right
-
Top
-
Bottom