507: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 39: Line 39:


<gallery>
<gallery>
File:Tek 507.jpg|507 on Cart
Tek 507.jpg|507 on Cart
File:Tek 507 and ps.jpg|507 with Power Supply
Tek 507 and ps.jpg|507 with Power Supply
File:Tek 507 at general electric.jpg|507 at General Electric
Tek 507 at general electric.jpg|507 at General Electric
File:Tek 507 block diagram.png|Block Diagram
Tek 507 block diagram.png|Block Diagram
File:Tek 507 sweep trigger and trip pulse.png|Sweep Trigger and Trip Pulse
Tek 507 sweep trigger and trip pulse.png|Sweep Trigger and Trip Pulse
File:Tek 507 time mark generator.png|Time Mark Generator
Tek 507 time mark generator.png|Time Mark Generator
File:Tek 507 vertical deflection.png|Vertical Deflection
Tek 507 vertical deflection.png|Vertical Deflection
File:Tek 507 horizontal amp.png|Horizontal Amplifier
Tek 507 horizontal amp.png|Horizontal Amplifier
File:Tek 507 crt circuit.png|CRT Circuit
Tek 507 crt circuit.png|CRT Circuit
File:Tek_507_heater_wiring.png|Heater Wiring
Tek_507_heater_wiring.png|Heater Wiring
File:Tek 507 power supply.png|Power Supply
Tek 507 power supply.png|Power Supply
Tek 507 ps 1.jpg
Tek 507 ps 1.jpg
Tek 507 ps 2.jpg
Tek 507 ps 2.jpg

Revision as of 15:19, 3 February 2018

{{{manufacturer}}} 
Power Industry scope
507 with Power Supply

Produced from 1959 to 1974

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix Type 507 was designed for the power industry for surge testing. It was introduced in 1959.

The scope was intended to operate in an environment of strong electromagnetic fields. It does not take plug-ins. The power supply is external, like in the 517, 551, and 555.

The vertical signal path of the 507 does not contain amplifiers. It has a 5 nanosecond risetime. The input impedance of the 507 is 72 Ω. The maximum sensitivity is deliberately low, at 50 V/cm.

The input attenuator is very unusual for Tek scopes. It is a switch with ten positions in "% of signal", where each step is 10%. The deflection signal is permanently AC-coupled and, unusually, the DC blocking capacitor is after the input attenuator.

The 507 has 20 kV of post-deflection acceleration, produced by four 1X2 tubes. The lower-voltage power supplies, located in the external box, are all tube except for selenium rectifiers for some of the lower voltages.

The 507 uses the T507 CRT.

Links

Pictures