3A2: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
(template, cat) |
||
Line 1: | Line 1: | ||
The Tektronix Type 3A2 is a dual-trace amplifier plug-in [[introduced in 1963]] | {{Plugin Sidebar 2| | ||
title=Tektronix Type 3A2 | | |||
summary=Dual trace amplifier plugin | | |||
image=3a2 front.jpg | | |||
caption=Type 3A2 front view | | |||
series=[[560-series scopes]] | | |||
introduced=1964 | | |||
discontinued=1972 | | |||
manuals= | |||
* [http://bama.edebris.com/download/tek/3a2/3a2.djvu Tektronix 3A2 Manual (DjVu)] | |||
}} | |||
The '''Tektronix Type 3A2''' is a dual-trace amplifier plug-in [[introduced in 1963]] | |||
for [[560-series scopes]]. It was designed for compatibility with the | for [[560-series scopes]]. It was designed for compatibility with the | ||
digital unit in the [[567]], e.g, the [[6R1]] or [[6R1A]]. | digital unit in the [[567]], e.g, the [[6R1]] or [[6R1A]]. | ||
Bandwidth | |||
Deflection factor | ==Specifications== | ||
{{BeginSpecs}} | |||
{{Spec | Bandwidth | 500 kHz }} | |||
{{Spec | Input impedance | 1 MΩ // 47 pF }} | |||
{{Spec | Deflection factor | 10 mV/div to 25 V/div }} | |||
{{EndSpecs}} | |||
==Internals== | |||
The input signal passes through | |||
compensated attenuators and then into a [[12AT7]] cathode-follower stage. | compensated attenuators and then into a [[12AT7]] cathode-follower stage. | ||
Channel switching in ALTERNATE mode is done using diodes. The output stage that | Channel switching in ALTERNATE mode is done using diodes. The output stage that | ||
drives the vertical deflection plates of the scope uses a pair of [[6BA8]] pentodes. | drives the vertical deflection plates of the scope uses a pair of [[6BA8]] pentodes. | ||
==Pictures== | |||
<gallery> | <gallery> | ||
File:3a2 front.jpg | |||
File:3a2 left.jpg | |||
File:3a2 right.jpg | |||
File:3a2 top.jpg | |||
File:3a2 bottom.jpg | |||
</gallery> | </gallery> | ||
[[Category:560 series plugins]] |
Revision as of 10:49, 1 September 2014
Template:Plugin Sidebar 2 The Tektronix Type 3A2 is a dual-trace amplifier plug-in introduced in 1963 for 560-series scopes. It was designed for compatibility with the digital unit in the 567, e.g, the 6R1 or 6R1A.
Specifications
Key Specifications
Bandwidth | 500 kHz |
---|---|
Input impedance | 1 MΩ // 47 pF |
Deflection factor | 10 mV/div to 25 V/div |
Internals
The input signal passes through compensated attenuators and then into a 12AT7 cathode-follower stage. Channel switching in ALTERNATE mode is done using diodes. The output stage that drives the vertical deflection plates of the scope uses a pair of 6BA8 pentodes.