{{Spec | Bandwidth | DC to 100 MHz on CH1 & CH2 for -15°C to +40°C and DC to 85MHz from +40°C to +55°C}}
{{Spec | Bandwidth | DC to 100 MHz on CH1 & CH2 for -15°C to +40°C and DC to 85 MHz from +40°C to +55°C}}
{{Spec | Rise time | 3.5 ns for 0°C to +40°C and 4.2ns from +40°C to +55°C}}}
{{Spec | Rise time | 3.5 ns for 0°C to +40°C and 4.2 ns from +40°C to +55°C}}}
{{Spec | Vertical Input Resistance/Capacitance  | 1MΩohm ±2%, Paralleled by 20pf }}
{{Spec | Input Impedance | 1 MΩ ±2% // 20 pF }}
{{Spec | Maximum Input Voltage - AC Coupled  | 500V DC + Peak AC or 500V<sub>p-p</sub> AC at < 1kHz  }}
{{Spec | Maximum Input Voltage - AC Coupled  | 500V DC + Peak AC or 500V<sub>p-p</sub> AC at < 1kHz  }}
{{Spec | Maximum Input Voltage - DC Coupled  | 250V DC+ Peak AC or 500V<sub>p-p</sub> AC at < 1kHz  }}
{{Spec | Maximum Input Voltage - DC Coupled  | 250V DC + Peak AC or 500V<sub>p-p</sub> AC at < 1kHz  }}
{{Spec | Trigger Coupling Modes | DC, AC, LF Reject, HF Reject}}
{{Spec | Trigger Coupling Modes | DC, AC, LF Reject, HF Reject}}
{{Spec | Channel Isolation | 100:1 at 25Mhz }}
{{Spec | Channel Isolation | 100:1 at 25 MHz }}
{{Spec | Z Axis Input | 5v p-p Signal causes noticeable modulation at normal intensity }}
{{Spec | Z Axis Input | 5 V<sub>p-p</sub> signal causes noticeable modulation at normal intensity }}
{{Spec | Z Axis Frequency response | DC to 50Mhz }}
{{Spec | Z Axis Frequency response | DC to 50 MHz }}
{{Spec | Output Signals | CH1 Vertical, A & B +Gate}}
{{Spec | Output Signals | CH1 Vertical, A & B +Gate}}
{{Spec | Calibrator Output  | ~1kHz, 300mV, Square Wave}}
{{Spec | Calibrator Output  | ~1 kHz, 300 mV, Square Wave}}
{{Spec | CRT  Graticule Area | 8cm X 10cm }}
{{Spec | CRT  Graticule Area | 8 cm × 10 cm }}
{{Spec | CRT  Phosphor| P31  }}
{{Spec | CRT  Phosphor| P31  }}
{{Spec | CRT Accelerating Potential | 18.5kV  }}
{{Spec | CRT Accelerating Potential | 18.5 kV }}
{{Spec | Line Voltage | 110/115/120/220/240 VAC ±10%,selected via primary voltage selector and regulating Range range selector assembly, 48 Hz to 440 Hz. }}
{{Spec | Line Voltage | 110/115/120/220/240 V<sub>AC</sub> ±10%, selected via primary voltage selector and regulating Range range selector assembly, 48 Hz to 440 Hz. }}
{{Spec | Power Consumption | 75 W @115 VAC/60Hz}}
{{Spec | Power Consumption | 75 W @ 115 V<sub>AC</sub> / 60 Hz}}
{{EndSpecs}}
{{EndSpecs}}



Revision as of 04:12, 1 August 2018

{{{manufacturer}}} 
Portable 100 MHz dual-trace scope
Tektronix 465 front

Produced from 1972 to 1983

Manuals
Manuals – Specifications – Links – Pictures


The Tektronix 465 is a portable 100 MHz dual-trace oscilloscope with dual time-bases. The 465 was very popular and Tek made them for quite a few years. It is all solid-state except for the CRT. It was introduced in November 1972. Bill Turner worked as a calibration technician for the 465 oscilloscope group.

There was no 465A but a 465B (int. 1980) with the same base specs but improved performance. The 475 is a 200 MHz sister model.

The optional DM44 multimeter attaches to the top of the instrument.

See also 465M.

Key Specifications

}
Bandwidth DC to 100 MHz on CH1 & CH2 for -15°C to +40°C and DC to 85 MHz from +40°C to +55°C
Rise time 3.5 ns for 0°C to +40°C and 4.2 ns from +40°C to +55°C
Input Impedance 1 MΩ ±2% // 20 pF
Maximum Input Voltage - AC Coupled 500V DC + Peak AC or 500Vp-p AC at < 1kHz
Maximum Input Voltage - DC Coupled 250V DC + Peak AC or 500Vp-p AC at < 1kHz
Trigger Coupling Modes DC, AC, LF Reject, HF Reject
Channel Isolation 100:1 at 25 MHz
Z Axis Input 5 Vp-p signal causes noticeable modulation at normal intensity
Z Axis Frequency response DC to 50 MHz
Output Signals CH1 Vertical, A & B +Gate
Calibrator Output ~1 kHz, 300 mV, Square Wave
CRT Graticule Area 8 cm × 10 cm
CRT Phosphor P31
CRT Accelerating Potential 18.5 kV
Line Voltage 110/115/120/220/240 VAC ±10%, selected via primary voltage selector and regulating Range range selector assembly, 48 Hz to 440 Hz.
Power Consumption 75 W @ 115 VAC / 60 Hz


Internals

The 465 uses tunnel diodes with Tek part number 152-0125-00, which are equivalent to TD3A, and 155-0032-00 chips (their -01 grade) as trigger amplifiers. The CRT is part number 154-0676-10.