515: Difference between revisions
No edit summary |
No edit summary |
||
Line 14: | Line 14: | ||
* first gain stage, differential amplifier, T-coil, [[12BY7]] | * first gain stage, differential amplifier, T-coil, [[12BY7]] | ||
* unity gain buffer, cathode follower, [[6DJ8]] | * unity gain buffer, cathode follower, [[6DJ8]] | ||
* output amplifier, differential amplifier, [[6CL6]] | * output amplifier, differential amplifier, T-coil, [[6CL6]] | ||
The horizontal amplifier uses half of a [[6DJ8]] as a buffer, followed by a 6DJ8 as a | The horizontal amplifier uses half of a [[6DJ8]] as a buffer, followed by a 6DJ8 as a |
Revision as of 10:33, 26 June 2011
The Tektronix 515 is a 15MHz single-trace all-tube oscilloscope. It does not use plug-ins. A rackmount version, the RM15 was also sold. There is also a 515A. The HV power supply uses tree 5642 rectifiers to produce +2325V for the CRT anode and -1675V for the CRT cathode. The LV power supply is linear, using a 6080 tube as the pass tube of the series regulator for +300V and +100V supply. The -150V supply is regulated by a 6AU5 tube. The voltage reference for the -150V supply is a 5651 tube. The 515 and 515A use selenium rectifiers. A kit was later made available for converting them to silicon rectifiers for improved reliability.
The vertical amplifier is fully differential, DC-coupled, and all tube. The stages are as follows:
- input buffer, cathode followers, 6AU6
- first gain stage, differential amplifier, T-coil, 12BY7
- unity gain buffer, cathode follower, 6DJ8
- output amplifier, differential amplifier, T-coil, 6CL6
The horizontal amplifier uses half of a 6DJ8 as a buffer, followed by a 6DJ8 as a differential amplifier and phase splitter, followed by the two halves of another 6DJ8 as the output cathode followers driving the horizontal CRT deflection plates.
The trigger is a 6DJ8 differential trigger amplifier followed by a 6DJ8 Schmitt trigger.
-
RM15 front view
-
RM15 side view
-
RM15 top view
-
RM15 bottom view
-
-