P6149: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 13: Line 13:


[[Category:1 MOhm Oscilloscope Probes]]
[[Category:1 MOhm Oscilloscope Probes]]
[[Category:Miniature modular probes]]
[[Category:Introduced in 1977]]
[[Category:Introduced in 1977]]

Revision as of 04:48, 17 December 2018

Tektronix P6149

The Tektronix P6149 is a passive ×10 voltage probe with a specified −3 dB point of 50 MHz. The impedance at the tip is 10 MΩ in parallel with 15.5 pF.

The probe connects to the oscilloscope with a BNC connector, and the compensation range is 20 pF to 62 pF.

The maximum input voltage is 500 V at DC, decreasing to about 25 V at 50 MHz.