Revision as of 04:55, 15 July 2019
The Tektronix P5210 is a 50 MHz high-voltage differential probe with a Tekprobe BNC connector.
Key Specifications
Maximum Voltage | 5,600 V (DC + pk AC) between leads, 1 kVRMS CAT III (2,2 kVRMSCAT II ) from ground; derate above 1.5 MHz |
---|---|
Attenuation | 100:1 or 1000:1 |
Bandwidth | 50 MHz (5 MHz limit switchable) |
Common-Mode Rejection Ratio | >3000:1 @ DC (500 V), >10,000:1 @ 60 Hz, >300:1 @ 100 kHz, >300:1 @ 1 MHz |
Input impedance | 16 MΩ // 3.5 pF between inputs; 8 MΩ // 7 pF between each input and ground |
Delay | 20 ns |
Output | 50 Ω output drives 1 MΩ // 15-20 pF scope input; scope bandwidth should be ≥200 MHz |
Features |
|
Manuals
- P5210 High Voltage Differential Probe Service Manual (no schematics)
Pictures
-
-
-
-
-
P5210 A