The '''Tektronix P6443''' TTL-threshold probe can be used with the [[1230]], [[1225]] and [[1220]] Logic Analyzers.  
The '''Tektronix P6443''' TTL-threshold probe can be used with the [[1230]], [[1225]] and [[1220]] Logic Analyzers.  


It is a 16-channel data acquisition probe with 4 clocks, 2 qualifier and 2 external trigger inputs.
It is a 16-channel data acquisition probe with 4 clocks, 2 qualifier and 2 external trigger inputs.
It uses the [[174-0752-00]], [[174-0763-00]], and [[174-0764-00]] lead set.
It uses the [[174-0752-00]], [[174-0763-00]], and [[174-0764-00]] lead set.


'''Note from operators manual:'''
'''Note from operators manual:'''
Line 59: Line 69:
* [http://www.barrytech.com/tektronix/probes/tekp6443.html P6443 @ barrytech.com]
* [http://www.barrytech.com/tektronix/probes/tekp6443.html P6443 @ barrytech.com]


==Photos==
==Pictures==
<gallery>
<gallery>
Tek p6443 1.jpg
Tek p6443 1.jpg

Latest revision as of 00:04, 14 February 2022

Tektronix P6443
16-channel logic analyzer probe
Tektronix P6443

Compatible with 1220 1225 1230

Produced from (?) to (?)

Manuals
  • please add


Manuals – Specifications – Links – Pictures

The Tektronix P6443 TTL-threshold probe can be used with the 1230, 1225 and 1220 Logic Analyzers.

It is a 16-channel data acquisition probe with 4 clocks, 2 qualifier and 2 external trigger inputs. It uses the 174-0752-00, 174-0763-00, and 174-0764-00 lead set.

Note from operators manual:

You cannot mix P6442 probes with P6443 or P6444 probes to take an acquisition.
If you acquire data on P6442 probes at the same time you try to sample data on P6443/P6444 probes, the acquired data from the P6443/P6444 probes will be invalid.

Specifications

The pin-out of the probe is given. (looking from the front)

Notch Notch Notch
QUAL CLK CLK CLK CLK EXT D14 D12 D10 D8 EXT D6 D4 D2 D0
QUAL GND GND GND GND GND D15 D13 D11 D9 GND D7 D5 D3 D1

Links

Pictures