7B80: Difference between revisions

From TekWiki
Jump to navigation Jump to search
m (→‎top: clean up, replaced: title=Tektronix → manufacturer=Tektronix | type=, series=7000-series scopes| → series=7000-series scopes|)
No edit summary
Line 1: Line 1:
{{Plugin Sidebar 2 |
{{Plugin Sidebar |
manufacturer=Tektronix | type=7B80 |
|manufacturer=Tektronix  
summary=400 MHz Timebase |
|type=7B80  
image=Tek 7b80 front.jpg |  
|summary=400 MHz Timebase  
caption=Tektronix 7B80 Timebase plug-in with Option 2|
|image=Tek 7b80 front.jpg  
introduced=1976 |
|caption=Tektronix 7B80 Timebase plug-in with Option 2
discontinued=1990 |
|introduced=1976  
series=7000-series scopes|
|discontinued=1990  
manuals=
|series=7000-series scopes
designers=
|manuals=
* [http://w140.com/smb/7b80_sm.pdf Tektronix 7B80 Manual (OCR, PDF)]
* [http://w140.com/smb/7b80_sm.pdf Tektronix 7B80 Manual (OCR, PDF)]
}}
}}
 
The '''Tektronix 7B80''' is a 400 MHz single time base plug-in without delay function for [[7000-series scopes]], typically the 7800 Series, e.g. [[7844]].
The '''Tektronix 7B80''' is a 400 MHz single time base plug-in without delay function for [[7000-series scopes]],  
typically the 7800 Series, e.g. [[7844]].
It uses the [[155-0126-00]] trigger amplifier followed by the [[155-0109-01]] trigger detector.  
It uses the [[155-0126-00]] trigger amplifier followed by the [[155-0109-01]] trigger detector.  



Revision as of 08:30, 13 August 2021

Tektronix 7B80
400 MHz Timebase
Tektronix 7B80 Timebase plug-in with Option 2

Compatible with [[7000-series scopes designers=]]

Produced from 1976 to 1990

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 7B80 is a 400 MHz single time base plug-in without delay function for 7000-series scopes, typically the 7800 Series, e.g. 7844. It uses the 155-0126-00 trigger amplifier followed by the 155-0109-01 trigger detector.

Option 2 adds support for X-Y mode via a "Display mode" switch (pictured). When X-Y mode is selected, the X-axis signal is taken from the internal trigger path.

The companion delaying timebase for use in 4-slot mainframes is the 7B85.

The 7B80 uses the ±50 V supplies from the mainframe.

Key Specifications

Sweep 10 ns/Div to 5 s/Div (1-2-5), ×10 magnifier (down to 1 ns/Div), variable sweep (up to ×2.5) and holdoff (up to ×2 sweep lengths at 20 ms/Div and faster)
Excluded sweep First 10 ns in 78xx, 79xx; First 20 ns in 77xx; First 50 ns in other mainframes
Trigger 50 mV or 0.3 Div up to 50 MHz, 250 mV or 1.5 Div up to 400 MHz; AC >30 Hz, LF REJ >30 kHz, HF REJ <50 kHz
Jitter <100 ps at 400 MHz
Ext. Trigger Max. 250 V DC+peak AC, 1 MΩ // 20 pF
Sweep/Trigger Modes Peak-Peak Auto, Auto, Norm, Single Sweep

Pictures