2215: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
m (clean up, replaced: {{Oscilloscope Sidebar | → {{Oscilloscope Sidebar | series=2200-series scopes |, 2000-series scopes → 2200-series scopes (2))
Line 1: Line 1:
{{Oscilloscope Sidebar |manufacturer=Tektronix |designers=|
{{Oscilloscope Sidebar | manufacturer=Tektronix |designers=|
series=2000-series scopes|model= 2215 |
series=2200-series scopes|model= 2215 |
image=Tek 2215a front.jpg |
image=Tek 2215a front.jpg |
caption=Tektronix 2215  |
caption=Tektronix 2215  |
Line 25: Line 25:
}}
}}


The '''Tektronix 2215''' is a portable dual-trace 60 MHz scope from the [[2000-series scopes|2000-series]] of low-cost analog scopes.
The '''Tektronix 2215''' is a portable dual-trace 60 MHz scope from the [[2200-series scopes|2000-series]] of low-cost analog scopes.


There are two revisions of the 2215, the major difference being in the power supply. Hence two service manuals.
There are two revisions of the 2215, the major difference being in the power supply. Hence two service manuals.

Revision as of 00:38, 11 August 2021

Tektronix 2215
60 MHz dual trace scope
Tektronix 2215

Produced from 1982 to (?)

Manuals

2215


2215A

Modifications

(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures


The Tektronix 2215 is a portable dual-trace 60 MHz scope from the 2000-series of low-cost analog scopes.

There are two revisions of the 2215, the major difference being in the power supply. Hence two service manuals.

There is also a 2215A (same specifications as 2215 with improved CRT intensity and bandwidth limit ?)

Key Specifications

     — Vertical
Deflection 2 mV to 10 V per division, 1-2-5
Rise time < 5.8 ns (calculated)
Bandwidth DC to >60 MHz, 20 mV/Div to 10 V/Div, 0 °C to +40 °C; >50 MHz in 2 mV/Div to 10 mV/Div ranges or from +40 °C to +50 °C
Input impedance 1 MΩ ±2% // 30 ±3 pF
Maximum Safe Input Voltage 400 V (dc + peak AC) or 800 Vp-p AC to 1 kHz or less
CMRR At least 10:1 at 10 MHz
     — Horizontal
Timebase 50 ns/Div to 500 ms/Div, 1-2-5,  ×10 magnifier, i.e. down to 5 ns/Div
     — Trigger
Sensitivity 0.4 Div internal / 50 mV external up to 2 MHz; 1.5 Div internal / 250 mV external up to 60 MHz
AC coupled trigger ≤10 Hz (-3 dB)
External trigger input max. 400 V (DC+peak AC) or 800 Vp-p AC to 1kHz or less; impedance 1 MΩ ±2% // 30 ±3 pF
Trigger modes Auto, Norm, TV Field
     — Miscellaneous
Features
  • X-Y operation
  • Probe adjust (0.5V at 1kHz)
Z axis input (intensity); DC to 5 MHz
CRT display area : 80 × 100 mm²
Weight 6.1 kg; 7.6 kg with front panel cover, accessories and pouch
Dimensions With feet and handle: 137 x 361 x 511 mm³

Links