131: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 18: | Line 18: | ||
{{Spec | Sensitivity | 1 mA/Div to 1 A/Div, 1-2-5 (scope input fixed at 50 mV/Div) }} | {{Spec | Sensitivity | 1 mA/Div to 1 A/Div, 1-2-5 (scope input fixed at 50 mV/Div) }} | ||
{{Spec | Noise | 0.1 mA<sub>p-p</sub> }} | {{Spec | Noise | 0.1 mA<sub>p-p</sub> }} | ||
{{Spec | | {{Spec | Risetime | 20 ns (eq. 17 MHz -3 dB) }} | ||
{{Spec | Lower frequency limit | 50 Hz }} | {{Spec | Lower frequency limit | 50 Hz }} | ||
{{Spec | Delay time | 32 ns typ. }} | {{Spec | Delay time | 32 ns typ. }} |
Revision as of 09:18, 21 January 2022
The Tektronix 131 is a current probe amplifier for the P6016 probe.
Key Specifications
Sensitivity | 1 mA/Div to 1 A/Div, 1-2-5 (scope input fixed at 50 mV/Div) |
---|---|
Noise | 0.1 mAp-p |
Risetime | 20 ns (eq. 17 MHz -3 dB) |
Lower frequency limit | 50 Hz |
Delay time | 32 ns typ. |
(all specifications are overall values including the P6016 probe)
Pictures
-
late 131 front
-
early 131 front
-
late 131 side view
-
early 131 overall view with P6016
-
schematic
-
Early 131
-
Early 131
-
Early 131
-
Early 131
-
Early 131
-
Early 131
-
Early 131