P6008: Difference between revisions
Jump to navigation
Jump to search
(Added sidebar, split into 2 sections for 2 types/generations, and fleshed out descriptions & specs) |
No edit summary |
||
Line 13: | Line 13: | ||
* [[Media:070-1173-00.pdf|Tektronix P6008 ENVIRONMENTAL PROBE Manual (PDF)]] | * [[Media:070-1173-00.pdf|Tektronix P6008 ENVIRONMENTAL PROBE Manual (PDF)]] | ||
}} | }} | ||
There were two different versions, or generations, of the '''Tektronix P6008''' ×10 passive voltage probe. Both were rated for use in temperatures up to 75 C (for the probe and cable.) | There were two different versions, or generations, of the '''Tektronix P6008''' ×10 passive voltage probe. Both were rated for use in temperatures up to 75 C (for the probe and cable.) | ||
===010-0130-00=== | |||
The '''early (1963) P6008 Probe (010-0130-00)''' was primarily designed for use with the [[82|Type 82]] and [[86|Type 86]] plug-ins in a [[580-series_scopes|580-series scope]], with 15 pF inputs. | |||
It came with a 3.5 foot cable. | |||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Attenuation | 10 × ±3% with 1 MΩ ±2% scope input }} | {{Spec | Attenuation | 10 × ±3% with 1 MΩ ±2% scope input }} | ||
Line 24: | Line 24: | ||
{{Spec | Bandwidth | 66 MHz w/Type 82 or 86 Plugin (63 MHz with x10 GAIN) }} | {{Spec | Bandwidth | 66 MHz w/Type 82 or 86 Plugin (63 MHz with x10 GAIN) }} | ||
{{Spec | Input capacitance | ~7 pF }} | {{Spec | Input capacitance | ~7 pF }} | ||
{{EndSpecs}} | {{EndSpecs}} | ||
===010-0130-01=== | |||
The '''later (1971) P6008 ENVIRONMENTAL PROBE (010-0130-01)''' can be compensated to a wider range of scope input capacitances, has wider bandwidth, but higher input capacitance. | |||
It came with a 6 foot cable. | |||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Attenuation | 10 × ±3% with scope input at 1 MΩ ±2% }} | {{Spec | Attenuation | 10 × ±3% with scope input at 1 MΩ ±2% }} | ||
Line 37: | Line 36: | ||
{{Spec | Input capacitance | 10-14 pF, depending on scope input capacitance }} | {{Spec | Input capacitance | 10-14 pF, depending on scope input capacitance }} | ||
{{EndSpecs}} | {{EndSpecs}} | ||
==Pictures== | ==Pictures== |
Revision as of 05:47, 4 December 2021
There were two different versions, or generations, of the Tektronix P6008 ×10 passive voltage probe. Both were rated for use in temperatures up to 75 C (for the probe and cable.)
010-0130-00
The early (1963) P6008 Probe (010-0130-00) was primarily designed for use with the Type 82 and Type 86 plug-ins in a 580-series scope, with 15 pF inputs. It came with a 3.5 foot cable.
Key Specifications
Attenuation | 10 × ±3% with 1 MΩ ±2% scope input |
---|---|
Compensation range | 15 pF (may be compensated to 20 pF with some loss of bandwidth) |
Bandwidth | 66 MHz w/Type 82 or 86 Plugin (63 MHz with x10 GAIN) |
Input capacitance | ~7 pF |
010-0130-01
The later (1971) P6008 ENVIRONMENTAL PROBE (010-0130-01) can be compensated to a wider range of scope input capacitances, has wider bandwidth, but higher input capacitance. It came with a 6 foot cable.
Key Specifications
Attenuation | 10 × ±3% with scope input at 1 MΩ ±2% |
---|---|
Compensation range | 15 pF to 55 pF |
Bandwidth | 100 MHz w/15 pF scope inputs |
Input capacitance | 10-14 pF, depending on scope input capacitance |
Pictures
-
P6008
-
Compensating Box Internals