P6015: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
Jaredcabot (talk | contribs) (Added P6015A product brochure, organised manual descriptions) |
||
Line 9: | Line 9: | ||
|discontinued=(?) | |discontinued=(?) | ||
|manuals= | |manuals= | ||
* [https://w140.com/p6015.pdf | * [https://w140.com/p6015.pdf P6015 Instruction Manual 070-0373-01] (Copyright date 1963) | ||
* [https://w140.com/P6015_070-0373-02.pdf | * [https://w140.com/P6015_070-0373-02.pdf P6015 Instruction Manual 070-0373-02] (Revision date 1985) | ||
* [https://w140.com/ | * [https://w140.com/tek_p6015a_mod.pdf P6015A Manual with Schematic 070-8223-04] | ||
* [https://w140.com/ | * [https://w140.com/P6015A_tek_original.pdf P6015A Instruction Manual 070-8223-05] | ||
* [https://w140.com/tek_p6007_p6009_p6015_cat.pdf | * [https://w140.com/tek_p6007_p6009_p6015_cat.pdf P6007 P6009 P6015 Catalog Description] | ||
* [[media:51W-8217-2.pdf|P6015A Product Brochure]] | |||
}} | }} | ||
The '''Tektronix P6015''' is a 1000× high-voltage probe usable up to 20 kV (40 kV peak pulse). | The '''Tektronix P6015''' is a 1000× high-voltage probe usable up to 20 kV (40 kV peak pulse). | ||
Revision as of 10:01, 27 February 2022
The Tektronix P6015 is a 1000× high-voltage probe usable up to 20 kV (40 kV peak pulse).
It can be operated with or without dielectric filling but without this filling, the maximum voltage is reduced to 13 kV (18 kV peak). The original filling material, Freon-114 aka Fluorocarbon 114 (R-114, CFC-114), is no longer available due to its ozone-depleting properties. In later models (P6015A), a silicone based replacement is used.
The P6015 has a compensating circuit at the scope end of the cable with multiple adjustable RC constants.
Key Specifications
Bandwidth | 75 MHz (10' cable), 25 MHz (25' cable) |
---|---|
Risetime | 4.67 ns (10' cable), 14 ns (25' cable) |
Attenuation | 1000× |
Input impedance | 100 MΩ // 3 pF |
Compensation range | 15-50 pF |
Max. input voltage |
|
Links
Pictures
-
Tektronix P6015 in box
-
-
-
-
-
-
-
Derating curves
-
Can of Freon Dielectric Fluid
-
Termination box