CT-6: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
Line 9: Line 9:
|discontinued=(?)
|discontinued=(?)
|manuals=
|manuals=
* [[Media:071-0453-00.pdf|Tektronix CT-6 Manual]]
* [[Media:071-0453-00.pdf|Tektronix CT-6 Manual 071-0453-00 Rev.A]]
}}
}}
'''Tektronix CT-6'''
The '''Tektronix CT-6''' is a miniature AC current probe suited for probing low-voltage, high-frequency circuits.


''please add description''
It has a fixed attached cable with an [[SMA connector]].
 
{{BeginSpecs}}
{{Spec | Bandwidth    | 250 kHz to 1.5 GHz (2 GHz typ.) }}
{{Spec | Rise time    | <233 ps (<170 ps typ.) }}
{{Spec | Sensitivity  | 5 mV/mA ±3% into 50 Ω load at 50 MHz }}
{{Spec | Max. Current | 120 mA<sub>RMS</sub> cont., 6 A peak }}
{{Spec | Insertion impedance | 1.1 Ω @ 10 MHz, 1.3 Ω @ 100 MHz }}
{{EndSpecs}}
 
==Links==
{{Documents|Link=CT-6}}


==Pictures==
==Pictures==

Latest revision as of 01:56, 20 November 2023

Tektronix CT-6
High Frequency AC Current Probe
Tektronix CT-6


Produced from (?) to (?)

Manuals


Manuals – Specifications – Links – Pictures

The Tektronix CT-6 is a miniature AC current probe suited for probing low-voltage, high-frequency circuits.

It has a fixed attached cable with an SMA connector.

Key Specifications

Bandwidth 250 kHz to 1.5 GHz (2 GHz typ.)
Rise time <233 ps (<170 ps typ.)
Sensitivity 5 mV/mA ±3% into 50 Ω load at 50 MHz
Max. Current 120 mARMS cont., 6 A peak
Insertion impedance 1.1 Ω @ 10 MHz, 1.3 Ω @ 100 MHz

Links

Documents Referencing CT-6

Pictures