The '''Tektronix P5205''' is a high-voltage active differential probe with a [[Tekprobe BNC connector]]. | The '''Tektronix P5205''' is a high-voltage active differential probe with a [[Tekprobe BNC connector]]. | ||
The [[P5210]] is a 50 MHz ×100/×1000 sister model. | |||
{{BeginSpecs}} | {{BeginSpecs}} |
Latest revision as of 09:41, 1 August 2023
The Tektronix P5205 is a high-voltage active differential probe with a Tekprobe BNC connector.
The P5210 is a 50 MHz ×100/×1000 sister model.
Key Specifications
Bandwidth | 100 MHz (5 MHz limit switchable) |
---|---|
Attenuation | 50:1 or 500:1 |
Maximum input |
|
Maximum nondestructive input | ±1.5 kV (DC + peak AC), ±1.3 kVRMS common mode |
CMRR | 80 dB @ 60 Hz, 50 dB @ 1 MHz |
Input impedance | 4 MΩ // 7 pF between each input and ground |
Output | 50 Ω output drives 1 MΩ // 15-20 pF scope input |
Features |
|
Links
- Tek P5205 HV differential probe teardown @ EEVBLOG (with internal photos)
Pictures
-
-
-
PCB, top view
-
PCB, bottom view