5CT1N: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
mNo edit summary
Line 1: Line 1:
Curve Tracer Plug-in for the 5000 series oscilloscopes.
The '''Tektronix 5CT1N''' Curve Tracer Plug-in for the 5000 series oscilloscopes, similar to the [[7CT1N]] for the 7000 series.


<gallery>
<gallery>
Line 6: Line 6:
Common Problems
Common Problems


C30 and C32 (100 uF, 25V) have a tendency to leak or short, causing associated resistors R30 and R32 (240, .25W, 5%) to overheat and fail. A good preventative maintenance procedure would be to replace these two capacitors with modern equivalents. Two 5CT1N units purchased online had this fault, and replacement of the capacitors and resistors restored proper operation.
C30 and C32 (100 &mu;F, 25 V) have a tendency to leak or short, causing associated resistors R30 and R32 (240 &Omega;, 0.25 W, 5%) to overheat and fail. A good preventative maintenance procedure would be to replace these two capacitors with modern equivalents. Two 5CT1N units purchased online had this fault, and replacement of the capacitors and resistors restored proper operation.


[[Category:Curve tracers]]
[[Category:Curve tracers]]
Line 12: Line 12:
[[Category:Specifications needed]]
[[Category:Specifications needed]]
[[Category:Manual needed]]
[[Category:Manual needed]]
[[Category:5000 series plugins]]

Revision as of 03:30, 20 May 2014

The Tektronix 5CT1N Curve Tracer Plug-in for the 5000 series oscilloscopes, similar to the 7CT1N for the 7000 series.

Common Problems

C30 and C32 (100 μF, 25 V) have a tendency to leak or short, causing associated resistors R30 and R32 (240 Ω, 0.25 W, 5%) to overheat and fail. A good preventative maintenance procedure would be to replace these two capacitors with modern equivalents. Two 5CT1N units purchased online had this fault, and replacement of the capacitors and resistors restored proper operation.