C30 and C32 ( | C30 and C32 (100 μF, 25 V) have a tendency to leak or short, causing associated resistors R30 and R32 (240 Ω, 0.25 W, 5%) to overheat and fail. A good preventative maintenance procedure would be to replace these two capacitors with modern equivalents. Two 5CT1N units purchased online had this fault, and replacement of the capacitors and resistors restored proper operation. | ||
[[Category:Curve tracers]] | [[Category:Curve tracers]] | ||
Line 12: | Line 12: | ||
[[Category:Specifications needed]] | [[Category:Specifications needed]] | ||
[[Category:Manual needed]] | [[Category:Manual needed]] | ||
[[Category:5000 series plugins]] |
Revision as of 03:30, 20 May 2014
The Tektronix 5CT1N Curve Tracer Plug-in for the 5000 series oscilloscopes, similar to the 7CT1N for the 7000 series.
Common Problems
C30 and C32 (100 μF, 25 V) have a tendency to leak or short, causing associated resistors R30 and R32 (240 Ω, 0.25 W, 5%) to overheat and fail. A good preventative maintenance procedure would be to replace these two capacitors with modern equivalents. Two 5CT1N units purchased online had this fault, and replacement of the capacitors and resistors restored proper operation.