P6230: Difference between revisions

Jump to navigation Jump to search
(1.5 GHz 50 Ohm probe)
 
(input hybrid info)
Line 6: Line 6:
The input signal runs through a 400 Ω resistor and a 1 μF capacitor, terminated in 50 Ω internally (switchable) or externally.
The input signal runs through a 400 Ω resistor and a 1 μF capacitor, terminated in 50 Ω internally (switchable) or externally.
The active circuit in the P6230, a standard NE5532 dual opamp, has the function of restoring and offsetting the input signal's DC component.
The active circuit in the P6230, a standard NE5532 dual opamp, has the function of restoring and offsetting the input signal's DC component.
As a modular subminature probe it shares accessories with many other Tektronix
subminature probes although the input hybrid is unique.  Tip color is yellow,
connector end color is blue, part number [[206-0279-00]].  It's end to end
resistance is 400 Ohms.


{{BeginSpecs}}
{{BeginSpecs}}