(1.5 GHz 50 Ohm probe) |
(input hybrid info) |
||
Line 6: | Line 6: | ||
The input signal runs through a 400 Ω resistor and a 1 μF capacitor, terminated in 50 Ω internally (switchable) or externally. | The input signal runs through a 400 Ω resistor and a 1 μF capacitor, terminated in 50 Ω internally (switchable) or externally. | ||
The active circuit in the P6230, a standard NE5532 dual opamp, has the function of restoring and offsetting the input signal's DC component. | The active circuit in the P6230, a standard NE5532 dual opamp, has the function of restoring and offsetting the input signal's DC component. | ||
As a modular subminature probe it shares accessories with many other Tektronix | |||
subminature probes although the input hybrid is unique. Tip color is yellow, | |||
connector end color is blue, part number [[206-0279-00]]. It's end to end | |||
resistance is 400 Ohms. | |||
{{BeginSpecs}} | {{BeginSpecs}} |