{{Spec | Bandwidth and Channels| 100 MHz in a 1, 2, 5 sequence; Bandwidth is at least 90 MHz at 2 mV/div; 2 Channels }}
{{Spec | Bandwidth       | 100 MHz (≥90 MHz at 2 mV/Div) }}
{{Spec | Deflection Factor| CH 1, 2: 5 mV/div to 5 V/div, all ±2%; Variable control can increase sensitivity to at least 2 mV/div.}}
{{Spec | Deflection     | CH1, CH2: 5 mV/Div to 5 V/Div, 1–2–5; all ±2%; Variable control can increase sensitivity to at least 2 mV/Div }}
{{Spec | Input Impedance| 1 MΩ ±2% and 20 pF ±2 pF }}
{{Spec | Input Impedance | 1 MΩ ±2% // 20±2 pF }}
{{Spec | Maximum Input Voltage| 400 V (DC + peak AC) or 500 V (p-p ac at ≤ 1 kHz) }}
{{Spec | Maximum Input   | 400 V (DC + peak AC) or 500 V (p-p ac at ≤ 1 kHz) }}
{{Spec | Sweep Speeds| A Time Base: 0.5 s/div to 50ns/div; B Time Base: 50 ms/div to 50 ns/div; A and B X10 magnifier extends max sweep to 5 ns/div }}
{{Spec | Sweep           | A Time Base 0.5 s/div to 50 ns/div; B Time Base 50 ms/div to 50 ns/div; A and B ×10 magnifier extends max sweep to 5 ns/div }}
{{Spec | Trigger Source| INT (CH1, 2), LINE, EXT (AC, DC, DC ÷ 10) }}
{{Spec | Trigger Source | INT (CH1, CH2), LINE, EXT (AC, DC, DC ÷ 10) }}
{{Spec | Probes| Two P6108A 100 MHz X10 probes, BNC connector with a readout pin }}
{{Spec | Probes         | Two P6108A 100 MHz ×10 probes, BNC connector with a readout pin }}
{{Spec | Power| 40 W max, 90 − 250 VAC, 48 − 440 Hz }}
{{Spec | Power           | 90 − 250 VAC, 48 − 440 Hz, 40 W max }}