TF-1 fixtures have been known to have issues with bad connections with the diode.
TF-1 fixtures have been known to have issues with bad connections with the diode.
In at least one case, a TF-1 has been made to work reliably by replacing the weak AlNiCo magnet that holds the axial leaded (magnetic) diode in place, by replacing it with a much stronger FeNdB magnet the same size (easily available on Ebay).
In at least one case, a TF-1 has been made to work reliably by replacing the weak AlNiCo magnet that holds the axial leaded (magnetic) diode in place, by replacing it with a much stronger FeNdB magnet the same size (easily available on Ebay).
The TF-1 was later superseded by an adapter [[017-0075-00]] to be used with the diode test jig [[013-0075-00]].