The '''Tektronix 453''' is a portable 50 MHz dual-trace oscilloscope [[introduced in 1966]] and produced until the mid-1970's.   
The '''Tektronix 453''' is a portable 50 MHz dual-trace oscilloscope [[introduced in 1966]] and produced until the mid-1970's.   


==Specifications==
[[Category:Specifications needed]]
''please add''
==Internals==
Initial versions had Nuvistor tubes in the front end as cathode-follower voltage buffers.   
Initial versions had Nuvistor tubes in the front end as cathode-follower voltage buffers.   
Later versions used FETs for the same purpose.   
Later versions used FETs for the same purpose.   
Line 53: Line 58:
</blockquote>
</blockquote>


==Specifications==
==Links==
[[Category:Specifications needed]]
* [http://www.diyguitarist.com/TestEquipment/Tektronix453.htm Paul Marossy's Tek 453 page]
''please add''
* [http://www.reprise.com/host/scopes/ Bill's Tektronix 453 and 454 Info Pages]


==Pictures==
==Pictures==

Revision as of 04:03, 26 September 2014

{{{manufacturer}}} 
50 MHz portable dual-trace scope
Tektronix 453 front

Produced from 1966 to 1974

Manuals
Manuals – Specifications – Links – Pictures


The Tektronix 453 is a portable 50 MHz dual-trace oscilloscope introduced in 1966 and produced until the mid-1970's.

Specifications

please add

Internals

Initial versions had Nuvistor tubes in the front end as cathode-follower voltage buffers. Later versions used FETs for the same purpose.

The vertical amplifier that drives the CRT deflection plates is a cascoded differential amplifier made of NPN transistors.

Triggering uses tunnel diodes, with a trigger preamplifier preceding the actual trigger circuit.

The 453 is almost entirely solid-state, even in its first version. The only tubes other than the CRT are the 5642 HV rectifiers and a few 8393 Nuvistor triode tubes.

Each horizontal deflection plate is driven by a common-emitter amplifier with feedback. The total CRT acceleration is 10 kV. The CRT cathode voltage is -2 kV and the CRT anode voltage is +8 kV. A Tektronix 453 consumes 100 W power and weighs 29 pounds (13.2 kg).

The 453 came with a rigid metal cap that protects the face of the scope while it is in transit. This cap has a compartment for storing probes and accessories.

Inside the 453, the electronics are rather densely packed in order for the scope to be compact. The top and bottom cover of the case separate simultaneously using and ingenious clasp. Removing the rear cover exposes the remaining fuses and circuitry.

There are two trigger/sweep units in a 453, thereby enabling delayed sweep mode. There are two delayed sweep modes: "B runs after A" and "B triggerable after A".

The 453 uses Nuvistors. The 453A, introduced in 1971, replaced the Nuvistors with transistors, extended the bandwidth to 60 MHz, increased the graticule from 6cm × 10cm to 8cm × 10cm, and introduced a mixed-sweep mode. Mixed-sweep mode starts the sweep at the "A" time/div rate and then, after a delay set by a ten-turn vernier dial, continues at the "B" sweep time/div rate.

The 453A Mod 127C appears in the 1971 Television Products Catalog, with the description:

With the Mod 127C, and Internal TV Sync Separator circuit permits stable internal line or Field-rate triggering from displayed composite video or composite sync waveforms. External /10 trigger sources are replaced by Internal TV Sync positions providing Line sync pulses to the B Sweep circuit and either Field or Line sync pulses to the A sweep circuit.