P6042: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(stub)
 
(specs, image)
Line 1: Line 1:
[[File:P6042.png|thumb|350px|right|P6042, catalog image]]
The '''Tektronix P6042''' is a DC to 50 MHz current probe.
The '''Tektronix P6042''' is a DC to 50 MHz current probe.


The sensor contains a current transformer for HF and a hall effect sensor for LF/DC components. 
The amplifier combines DC/LF and HF signals.
{{BeginSpecs}}
{{Spec | Bandwidth | DC to 50 MHz (-3 dB) }}
{{Spec | Rise time | 7 ns }}
{{Spec | Ranges | 1 mA/Div to 1 A/Div (1-2-5) }}
{{Spec | Output | to 50 Ω scope input at 50 mV/Div }}
{{Spec | Maximum input | 10 A DC+peak AC in 5 mA to 1 A ranges, 0.5 A in 1 mA and 2 mA ranges }}
{{Spec | Power | 90-136 or 180-272 V, 20 W}}
{{EndSpecs}}
==Manuals==
* [http://bama.edebris.com/manuals/tek/p6042/ P5042 manual @ BAMA]
==Links==
* [http://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_other/P6042.htm Tek P6042 page @ amplifier.cd]
* [http://www.barrytech.com/tektronix/probes/tekp6042.html Tek P6042 page @ barrytech.com]
* [http://www.radiomuseum.org/r/tektronix_current_probe_dc_to_50_m.html Tek P6042 page @ radiomuseum.org]
* [http://www.pa4tim.nl/?p=3135 P6042 repair by Fred, PA4TIM]
==Pictures==
[[Category:Image needed]] ''please add''




[[Category:Oscilloscope current probes]]
[[Category:Oscilloscope current probes]]

Revision as of 03:57, 24 January 2015

P6042, catalog image

The Tektronix P6042 is a DC to 50 MHz current probe.

The sensor contains a current transformer for HF and a hall effect sensor for LF/DC components. The amplifier combines DC/LF and HF signals.

Key Specifications

Bandwidth DC to 50 MHz (-3 dB)
Rise time 7 ns
Ranges 1 mA/Div to 1 A/Div (1-2-5)
Output to 50 Ω scope input at 50 mV/Div
Maximum input 10 A DC+peak AC in 5 mA to 1 A ranges, 0.5 A in 1 mA and 2 mA ranges
Power 90-136 or 180-272 V, 20 W

Manuals

Links

Pictures

please add