067-0587-02: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(images added)
No edit summary
Line 14: Line 14:


{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | |      — ''GAIN mode'' — }}
{{SpecGroup | GAIN mode }}
{{Spec | Staircase accuracy | ± 0.3% in ± 3 Div, ± 0.5% in ± 4 Div, Linearity ± 0.2% of 10 Div }}
{{Spec | Staircase accuracy | ± 0.3% in ± 3 Div, ± 0.5% in ± 4 Div, Linearity ± 0.2% of 10 Div }}
{{Spec |      — ''STEP RESP mode'' — }}
{{SpecGroup |  STEP RESP mode }}
{{Spec | Amplitude | 2 to 10 Div }}
{{Spec | Amplitude | 2 to 10 Div }}
{{Spec | Position  | Top at least ±5 Div from center of screen }}
{{Spec | Position  | Top at least ±5 Div from center of screen }}
Line 22: Line 22:
{{Spec | Repetition rate | 10 Hz to 1 MHz in decade steps, 0.1 %}}
{{Spec | Repetition rate | 10 Hz to 1 MHz in decade steps, 0.1 %}}
{{Spec | Pretrig Out | 0.5 V into 50 Ω, 55 to 95 ns lead time (internally variable) }}
{{Spec | Pretrig Out | 0.5 V into 50 Ω, 55 to 95 ns lead time (internally variable) }}
{{Spec |      — ''FREQ RESP mode'' — }}
{{SpecGroup |  FREQ RESP mode }}
{{Spec | Input impedance | 50 Ω }}
{{Spec | Input impedance | 50 Ω }}
{{Spec | Input range    | 0.5 to 1 V<sub>p-p</sub> }}
{{Spec | Input range    | 0.5 to 1 V<sub>p-p</sub> }}
Line 47: Line 47:


[[Category:7000 series special-function plugins]]
[[Category:7000 series special-function plugins]]
[[Category:Specifications needed]]
[[Category:Calibration fixtures]]
[[Category:Calibration fixtures]]

Revision as of 08:10, 28 March 2015

Template:Plugin Sidebar 2 The Tektronix 067-0587-02 is a signal standardizer (calibration) plug-in for 7000-series scopes. It is a complete redesign of the 067-0587-01 standardizer. It provides a calibrated staircase at 1 line/Div in Gain mode, a fast-rising pulse in Step Resp mode, an input for a CW signal to test bandwidth, and an input for a common mode test signal.

Key Specifications

     — GAIN mode
Staircase accuracy ± 0.3% in ± 3 Div, ± 0.5% in ± 4 Div, Linearity ± 0.2% of 10 Div
     — STEP RESP mode
Amplitude 2 to 10 Div
Position Top at least ±5 Div from center of screen
Rise time < 150 ps
Repetition rate 10 Hz to 1 MHz in decade steps, 0.1 %
Pretrig Out 0.5 V into 50 Ω, 55 to 95 ns lead time (internally variable)
     — FREQ RESP mode
Input impedance 50 Ω
Input range 0.5 to 1 Vp-p
Flatness ± 3% from 3 MHz to 1 GHz

Internals

The 067-0587-02 is based on a number of Tektronix custom ICs from the 1 GHz 7104 scope generation, such as the 155-0160-00 trigger amplifier + source select chip and the 155-0175-00 trigger amplifier chip.

The mode selector switch is a special elastomer-based cam switch. The manual warns that while it can be cleaned if proper procedure is followed (note some screws are labelled "do not remove" on the cover!), only at the factory can (could ...) it be repaired/re-assembled completely.

Links

Pictures