P6202: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
(specs) |
||
Line 1: | Line 1: | ||
The '''Tektronix P6202''' is a 500 MHz active 10× FET probe with 50 Ω output impedance. | |||
{{BeginSpecs}} | |||
{{Spec | Bandwidth | DC to 500 MHz (16 Hz lower limit with additional AC coupling tip) }} | |||
{{Spec | Rise time | < 0.7 ns }} | |||
{{Spec | Attenuation | 10 : 1 (100 : 1 with additional 10× attenuator tip) }} | |||
{{Spec | Input impedance | 10 MΩ // 2 pF (add 2 pF for AC coupling tip) }} | |||
{{Spec | Input range | ± 6 V (± 60 V with additional 10× attenuator tip) }} | |||
{{Spec | DC Offset range | ± 55 V (± 200 V with additional 10× attenuator tip) }} | |||
{{Spec | Max input | ± 200 V (nondestructive) }} | |||
{{EndSpecs}} | |||
==Manuals== | |||
* [http://w140.com/tek_p6202a.pdf Tektronix P6202A Manual (PDF)] | * [http://w140.com/tek_p6202a.pdf Tektronix P6202A Manual (PDF)] | ||
* [http://w140.com/tekscope_1976vol8no2_p6202.pdf P6202 Article in 1976 Volume 8 Number 2 Tekscope (PDF)] | * [http://w140.com/tekscope_1976vol8no2_p6202.pdf P6202 Article in 1976 Volume 8 Number 2 Tekscope (PDF)] |
Revision as of 00:31, 7 April 2015
The Tektronix P6202 is a 500 MHz active 10× FET probe with 50 Ω output impedance.
Key Specifications
Bandwidth | DC to 500 MHz (16 Hz lower limit with additional AC coupling tip) |
---|---|
Rise time | < 0.7 ns |
Attenuation | 10 : 1 (100 : 1 with additional 10× attenuator tip) |
Input impedance | 10 MΩ // 2 pF (add 2 pF for AC coupling tip) |
Input range | ± 6 V (± 60 V with additional 10× attenuator tip) |
DC Offset range | ± 55 V (± 200 V with additional 10× attenuator tip) |
Max input | ± 200 V (nondestructive) |