2215: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 9: Line 9:
* [http://w140.com/tek_2215_service.pdf Tektronix 2215 Manual (PDF)]
* [http://w140.com/tek_2215_service.pdf Tektronix 2215 Manual (PDF)]
* [http://w140.com/kurt/tektronix_2215a.pdf Tektronix 2215A Manual (PDF)]
* [http://w140.com/kurt/tektronix_2215a.pdf Tektronix 2215A Manual (PDF)]
<small>
'''Modifications '''
* [http://hakanh.com/dl/docs/kitinstructions/045-0034-00.pdf 045-0034-00 CRT Power supply improvement] (1982)
</small>
}}
}}


Line 15: Line 19:
There is also a 2215A (same specifications as 2215 with improved CRT intensity and bandwidth limit ?)
There is also a 2215A (same specifications as 2215 with improved CRT intensity and bandwidth limit ?)


==Specifications==
{{BeginSpecs}}
=== Vertical ===
{{SpecGroup | Vertical }}
* 2mV to 10V per division in a 1-2-5 sequence
{{Spec | Deflection | 2 mV to 10 V per division, 1-2-5 }}
* Step Response : Rise time < 5.8ns. Calculated from the formula "Rise Time = 0.35 / BW(in MHz)"
{{Spec | Rise time | < 5.8 ns (calculated)}}
* Bandwidth (+0 to +40 C)
{{Spec | Bandwidth | DC to >60 MHz, 20 mV/Div to 10 V/Div, 0 °C to +40 °C;  >50 MHz in 2 mV/Div to 10 mV/Div ranges or from +40 °C to +50 °C}}
** 20mV to 10V per div : DC to > 60MHz
{{Spec | Input impedance | 1 MΩ ±2% // 30 ±3 pF }}
** 2mV to 10mV per div : DC to > 50MHz
{{Spec | Maximum Safe Input Voltage | 400 V (dc + peak AC) or 800 V<sub>p-p</sub> AC to 1 kHz or less }}
* Bandwidth (+40 to +50 C) : DC to > 50MHz
{{Spec | CMRR | At least 10:1 at 10 MHz }}
* Input Characteristics : 1M +- 2% ; 30pF +- 3pF
{{EndSpecs}}
* Maximum Safe Input Voltage : 400V (dc + peak AC) or 800V p-p AC to 1kHz or less
* CMRR : At least 10:1 at 10MHz.


=== Trigger ===
=== Trigger ===

Revision as of 02:18, 17 December 2016

{{{manufacturer}}} 
60 MHz dual trace scope
Tektronix 2215

Produced from 1982 to (?)

Manuals

Modifications

(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures


The Tektronix 2215 is a portable dual-trace 60 MHz scope from the 2000-series of low-cost analog scopes.

There is also a 2215A (same specifications as 2215 with improved CRT intensity and bandwidth limit ?)

Key Specifications

     — Vertical
Deflection 2 mV to 10 V per division, 1-2-5
Rise time < 5.8 ns (calculated)
Bandwidth DC to >60 MHz, 20 mV/Div to 10 V/Div, 0 °C to +40 °C; >50 MHz in 2 mV/Div to 10 mV/Div ranges or from +40 °C to +50 °C
Input impedance 1 MΩ ±2% // 30 ±3 pF
Maximum Safe Input Voltage 400 V (dc + peak AC) or 800 Vp-p AC to 1 kHz or less
CMRR At least 10:1 at 10 MHz

Trigger

  • Auto / Norm
    • <= 2MHz : 0.4 division internal or 50mV external
    • <= 60 MHz : 1.5 divisions internal or 250mV external
  • TV Field
  • External input :
    • Maximum Input Voltage : 400V (dc + peak AC) or 800V p-p AC to 1kHz or less
    • Input Characteristics : 1M +- 2% ; 30pF +- 3pF
    • AC Coupled : 10Hz or less at lower -3dB point

Horizontal

  • 0.5s to 50ns per division in a 1-2-5 sequence. X10 Magnifier extends to 5ns per div.

Misc

  • X-Y operation
  • Probe adjust (0.5V at 1kHz)
  • Z axis input (intensity); DC to 5MHz
  • CRT display area : 80 x 100mm
  • Weight : 6.1kg; 7.6kg with front panel cover + accessories and pouch
  • Dimensions with feet and handle: 137 x 361 x 511 mm