* Maximum calibrated sensitivity: 1 mV/div
* Maximum calibrated sensitivity: 1 mV/div
* Minimum calibrated sensitivity: 20 V/div
* Minimum calibrated sensitivity: 20 V/div
* Input impedance: 1 megohm in parallel with 20 pF
* Input impedance: 1 MΩ in parallel with 20 pF
* Frequency response is DC to 45 MHz, except in maximum sensitivity setting, where it is 35 MHz
* Frequency response is DC to 45 MHz, except in maximum sensitivity setting, where it is 35 MHz
* CMRR below 100 kHz is 20,000:1
* CMRR below 100 kHz is 20,000:1
* Maximum input current: less than 1 nA
* Maximum input current: less than 1 nA
* Comparison voltage range: -6 V to +6 V
* Comparison voltage range: -6 V to +6 V
* Comparison voltage accuracy (0C to 40C): +/- (0.1% + 5 mV)
* Comparison voltage accuracy (0 °C to 40 °C): +/- (0.1% + 5 mV)
 
 


==Pictures==
==Pictures==
<gallery>
<gallery>
Image:10a1 front.jpg
10a1 front.jpg
Image:10a1 left.jpg
10a1 left.jpg
Image:10a1 right.jpg
10a1 right.jpg
Image:10a1 gear1.jpg
10a1 gear1.jpg
Image:10a1 top.jpg
10a1 top.jpg
Image:10a1 bottom.jpg
10a1 bottom.jpg
Image:Tek 10a1 input amp2.png|Input Amplifier Schematic
Tek 10a1 input amp2.png|Input Amplifier Schematic
</gallery>
</gallery>


[[Category:647 plugins]]
[[Category:647 plugins]]

Revision as of 10:49, 14 May 2017

Template:Plugin Sidebar 2

The Tektronix 10A1 is a differential amplifier plug-in for 647 scopes. The input amplifier uses 8056 nuvistor triodes for the input cathode followers. The 10A1 is a comparator, meaning that it has a built-in precision variable DC voltage source that can be added or subtracted from the signal voltage.

Specifications

  • Maximum calibrated sensitivity: 1 mV/div
  • Minimum calibrated sensitivity: 20 V/div
  • Input impedance: 1 MΩ in parallel with 20 pF
  • Frequency response is DC to 45 MHz, except in maximum sensitivity setting, where it is 35 MHz
  • CMRR below 100 kHz is 20,000:1
  • Maximum input current: less than 1 nA
  • Comparison voltage range: -6 V to +6 V
  • Comparison voltage accuracy (0 °C to 40 °C): +/- (0.1% + 5 mV)

Pictures