The Tektronix Type S-311 Programmable Dual-Trace Sampling Plug-In Unit  
The Tektronix Type S-311 Programmable Dual-Trace Sampling Plug-In Unit  
is a [[560-series plug-ins|560-series plug-in]] designed for use
is a [[560-series plug-ins|560-series plug-in]] designed for use
with the Tektronix [[S2000]] and [[S3000]]­ Series Systems.  
with the Tektronix [[S2000]] and [[S3000]]­ Series Systems.
In contrast to the [[3S6]] which uses external sampling heads,
the S-311 contains two samplers internally, like the [[3S76]] or [[3S1]].
However, unlike the 3S76 and 3S1, the S-311 gets its signal inputs via
BNC connectors on the rear panel.
The input impedance of each input is 50 ohms.
The the S-311 is inserted into the mainframe,
the BNC input connectors of the S-311 must be manually connected.
The input connectors are not designed to pair with a corresponding
connector in the plug-in bay bulkhead.
The S-311 can be connected to the device under test via 50-Ω cables,
or via probes designed for a 50-Ω system,
e.g., the [[P6026]], [[P6034]], [[P6032]], or [[P6035]].
 
The S-311 does not contain a signal delay.
The BNC signal input connectors on the rear panel of the S-311
are connected by short coaxial cables to the sampling bridge.


* [[Media:070-0468-01.pdf|Tektronix S-311 Manual (PDF)]]
* [[Media:070-0468-01.pdf|Tektronix S-311 Manual (PDF)]]

Revision as of 12:22, 29 December 2017

The Tektronix Type S-311 Programmable Dual-Trace Sampling Plug-In Unit is a 560-series plug-in designed for use with the Tektronix S2000 and S3000­ Series Systems. In contrast to the 3S6 which uses external sampling heads, the S-311 contains two samplers internally, like the 3S76 or 3S1. However, unlike the 3S76 and 3S1, the S-311 gets its signal inputs via BNC connectors on the rear panel. The input impedance of each input is 50 ohms. The the S-311 is inserted into the mainframe, the BNC input connectors of the S-311 must be manually connected. The input connectors are not designed to pair with a corresponding connector in the plug-in bay bulkhead. The S-311 can be connected to the device under test via 50-Ω cables, or via probes designed for a 50-Ω system, e.g., the P6026, P6034, P6032, or P6035.